Transthoracic electrical bioimpedence cardiac output: comparison with multigated equillibrium radionuclide
Arunodaya R Gujjar1, K Muralidhar, Abhijit Bhandopadhyaya
1National Institute of Mental Health and Neurosciences, Bangalore, 560029, India.
Introduction:
Thoracic electrical bioimpedance (TEB) for measuring cardiac output (CO) is being explored increasingly as an alternative to pulmonary artery catheter. The major advantage of this technology is that it is non-invasive and easy to perform. Several studies have compared it to thermodilution cardiac output using PA catheter, with variable correlation. Multigated radionuclide equilibrium cardiography (RNEC) method of cardiac output measurement is known to be reliable.
Objective:
To compare cardiac output measured by thoracic electrical bioimpdenace with that measured by multigated radionuclide equilibrium cardiography.
Patients And Methods:
CO studies were performed sequentially at a single sitting by TEB and RNEC methods among patients with cardiac symptoms referred for radionuclide study as part of their evaluation. TEB CO was measured by placing two pairs of electrodes on either side of neck and two other pairs on either side of the lower chest. Stroke volume was estimated from the sequential changes in transthoracic electrical bioimpedance induced by rhythmic aortic blood flow, using Kubicek equation. RNEC-CO was measured by intravenous injection of radio-active Technitium-tagged RBCs followed by ECG gated blood pool imaging over the chest (MUGA study). Bland-Altman analysis was used to compare the measurements.
Results:
A total of 32 subjects with proven or suspected ischemic heart disease, but without overt cardiac failure, edema or arrhythmias were studied (M:F::26:6; mean age: 48 +/- 12 years). The mean TEB-CO was 3.54 +/- 1.052 l/min and mean RNEC-CO was 3.907 +/- 0.952 l/min. Correlation coefficient (r) for these measurements was 0.67 (p < 0.01), with bias: -0.421 l/min; precision: 1.557 l/min; and percentage error of measurement: 42.35%.
Conclusions:
This study observed a moderate correlation between TEB and RNEC methods of CO measurement. Further studies are indicated to explore the relative utility of TEB in comparison with RNEC as well as other methods of CO measurement before considering its use in patients with ischemic heart disease.
Related Concept Videos
Electrocardiogram
Three major waveforms are present in a typical ECG recording: the P wave, the QRS complex, and the T...
Cardiac Output I:Effect of Heart Rate on Cardiac Output
Cardiac output (CO) refers to the total amount of blood ejected by one of the ventricles in liters per minute (L/min). In a resting adult, CO ranges from 5 to 6 L/min, adjusting according to the body's metabolic requirements.
Effect of Heart Rate on Cardiac Output
Cardiac output adapts to metabolic demands during stress, physical activity, or illness. The autonomic nervous system regulates heart rate via the sinoatrial node. The parasympathetic nervous system decreases heart rate...
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...