The effect of endotracheal suction on regional tidal ventilation and end-expiratory lung volume
D G Tingay1, B Copnell, C A Grant
1Department of Neonatology, Royal Children's Hospital, Melbourne, VIC, Australia. david.tingay@rch.org.au
Purpose:
To examine the impact of different endotracheal tube (ETT) suction techniques on regional end-expiratory lung volume (EELV) and tidal volume (V(T)) in an animal model of surfactant-deficient lung injury.
Methods:
Six 2-week old piglets were intubated (4.0 mm ETT), muscle-relaxed and ventilated, and lung injury was induced with repeated saline lavage. In each animal, open suction (OS) and two methods of closed suction (CS) were performed in random order using both 5 and 8 French gauge (FG) catheters. The pre-suction volume state of the lung was standardised on the inflation limb of the pressure-volume relationship. Regional EELV and V(T) expressed as a proportion of the impedance change at vital capacity (%Z (VCroi)) within the anterior and posterior halves of the chest were measured during and for 60 s after suction using electrical impedance tomography.
Results:
During suction, 5 FG CS resulted in preservation of EELV in the anterior (non-dependent) and posterior (dependent) lung compared to the other permutations, but these only reached significance in the anterior regions (p < 0.001 repeated-measures ANOVA). V(T) within the anterior, but not posterior lung was significantly greater during 5FG CS compared to 8 FG CS; the mean difference was 15.1 [95% CI 5.1, 25.1]%Z (VCroi). Neither catheter size nor suction technique influenced post-suction regional EELV or V(T) compared to pre-suction values (repeated-measures ANOVA).
Conclusions:
ETT suction causes transient loss of EELV and V(T) throughout the lung. Catheter size exerts a greater influence than suction method, with CS only protecting against derecruitment when a small catheter is used, especially in the non-dependent lung.
Related Concept Videos
Mechanical Ventilation II: Invasive Ventilation
Negative-Pressure Ventilators
Negative-pressure ventilators create a vacuum around the chest or body to draw air into the lungs, simulating breathing. This method does not require an...
Respiratory Volumes
Tidal Volume (TV) Tidal volume (TV) is the air inhaled or exhaled in a...
Endotracheal Intubation I: Procedure
The ET tube comprises various components, including a standard adaptor to attach a bag-valve-mask (BVM) or ventilator, a cuff, a pilot balloon, and radiopaque markings along its length to measure the insertion distance. The tube sizes...
Endotracheal Tube Extubation
Procedure
Extubation removes the endotracheal tube (ETT) from the patient on mechanical ventilation. It requires a well-coordinated, multidisciplinary approach involving physicians, nurses, respiratory therapists, and other healthcare professionals.
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...