Related Experiment Video
Updated: Jun 15, 2026

A New Straightforward Method for Lipophilicity (logP) Measurement using 19F NMR Spectroscopy
Published on: January 30, 2019
Comparison of physicochemical and gas chromatographic polarity measures for simple organic compounds
Károly Héberger1, Igor G Zenkevich
1Chemical Research Center, Hungarian Academy of Sciences, P.O. Box 17, H-1525 Budapest, Hungary. heberger@chemres.hu
Abstract:
The comparison of different polarity measures (parameters, descriptors, variables, scales, etc.) indicates that evaluation of interrelations between these measures is important for better understanding and interpretation of chemical and/or analytical data, especially for chromatographic separation. The best linear correlation between gas chromatographic and non-chromatographic polarity descriptors is revealed for the first time: this pair of variables is the difference of gas chromatographic retention indices on standard polar and non-polar phases as well as the difference between non-dimensional indices of boiling points (known in chromatography since mid-1980s as dispersion indices) and indices of molar refractions. The correlation helps chromatographers to find preferable chemical variables (features) to understand better the separation phenomena and to find better correlations in QSRR models. Principal component analysis (PCA) of ten frequently applied polarity measures shows their similarity and, at the same time, it shows the absence of anomalies within the set of simple organic molecules. A novel ranking method for ten polarity parameters points out that the two most informative polarity measures are (i) the non-dimensional index for boiling point and (ii) the difference in chromatographic retention indices on standard polar and non-polar stationary phases. On the other hand, the hydrophobicity parameter, log P, sometimes considered as polarity parameter in HPLC seems to be the worst one in description of "polarity" in gas chromatography. Surprisingly, such polarity measures like dipole moment and permittivity used often in organic chemistry does not provide the best correlation with gas chromatographic polarity measures.
More Related Videos
11:44Qualitative Characterization of the Aqueous Fraction from Hydrothermal Liquefaction of Algae Using 2D Gas Chromatography with Time-of-flight Mass Spectrometry
Published on: March 6, 2016
11:44Using Cyclic Voltammetry, UV-Vis-NIR, and EPR Spectroelectrochemistry to Analyze Organic Compounds
Published on: October 18, 2018
Related Concept Videos
Molecular Shape and Polarity
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Measuring Reaction Rates
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Bond Polarity, Dipole Moment, and Percent Ionic Character