Chromatographic Fingerprinting by Template Matching for Data Collected by Comprehensive Two-Dimensional Gas Chromatography
Published on: September 2, 2020
Application of Gas Chromatographic Retention Indices to GC and GC-MS Identification with Variable Limits for
1Institute for Chemistry, St. Petersburg State University, 198504 St. Petersburg, Russia.
Abstract:
The potential of a new algorithm for comparing experimental and reference values of gas chromatographic retention indices (RIs) is discussed. This algorithm is designed to minimize significant elements of uncertainty typical of numerous contemporary recommendations, primarily, the fixed limiting values of permissible deviations between experimental and reference RI-values, ΔRI = (RIref - RIexp). The algorithm proposed implies the calculation of deviations, ΔRI, for the most reliably identified constituents of multicomponent mixtures in different parts of chromatograms with known reference RI values, followed by calculation of coefficients of regression equations ΔRI = (RIref - RIexp) = aRIexp + b for both of the reduced sets of analytes. This equation allows for the recalculation of experimentally determined RIs into corrected values RIcorr = RIexp + ΔRI, which means replacing the fixed "global" limits with data-dependent adaptive thresholds for different constituents of multicomponent samples. Such an algorithm makes it possible to use reference RI values for semi-standard nonpolar polydimethylsiloxane phases (with 5% phenyl groups and others) for the comparison with data determined with standard nonpolar polydimethylsiloxanes and vice versa, as well as to minimize the influence of possible erroneous reference RI data. It is applicable both to statistically processed reference data and to results of single measurements. Both of these kinds of reference data are known and presented in contemporary RI databases, e.g., in the NIST RI database.
More Related Videos
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Types of Detectors-II