Related Experiment Video
Updated: Jun 14, 2026

A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
Examining the accumulated oxygen deficit method in front crawl swimming
V M Reis1, D A Marinho, F B Policarpo
1Department of Sport Sciences, Exercise and Health, University of Trás-os-Montes and Alto Douro, Vila Real, Portugal. vreis@utad.pt
Abstract:
The present study investigated the Accumulated Oxygen Deficit (AOD) method in front crawl swimming with the aims to assess the robustness of the oxygen uptake/swimming velocity regression line and to quantify the precision of the AOD. Twenty-nine male swimmers performed two swimming tests in different days, with a 24 h recovery between tests: a graded test and an all-out test. The all-out test was performed either in 100 m (n=11), 200 m (n=13) or 400 m (n=5). Through all testing expired gases were collected breath by breath and analysed with a K4b2 Gas Analyser (Cosmed, Rome, Italy) connected to an AquaTrainer Valve (Cosmed, Rome, Italy). The error of oxygen uptake/swimming velocity regression lines was approximately 4-5 ml x kg (-1) x min (-1)) and the regressions allowed an extrapolation of the energy cost to higher intensities with a standard error of prediction of approximately 3-4 ml x kg (-1) x min (-1). However, the data variability was considerable (95% confidence intervals of the linear extrapolation larger than 13 ml x kg (-1) x min (-1)). The AOD imprecision varied among the three distance events from approximately 3-13 ml x kg (-1). These absolute errors are small, considering the time that subjects took to cover the three distances, but relative to the AOD values that were estimated they can be considered high, especially in the 400 m bout.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Oxygen Transport in the Blood

