Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Insulin: Dosing Regimen and Adverse Effects01:16

Insulin: Dosing Regimen and Adverse Effects

Insulin-replacement therapy usually includes both long-acting insulin (basal) and short-acting insulin (to cater to postprandial needs). In a diverse group of type 1 diabetes patients, the average daily insulin dose is typically 0.5-0.7 units/kg body weight. However, obese patients and pubertal adolescents may need more due to insulin resistance.
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Hazard Analysis and Critical Control Points (HACCP)01:30

Hazard Analysis and Critical Control Points (HACCP)

Hazard Analysis and Critical Control Points (HACCP) is a science-based, preventive system used globally to ensure food safety by identifying, evaluating, and controlling biological, chemical, and physical hazards throughout food production. Originally developed by NASA and the Pillsbury Company for astronaut food, HACCP is now a core component of the Codex Alimentarius.HACCP operates on prerequisite programs—such as Good Manufacturing Practices (GMPs), sanitation procedures, and supplier...
Insulin Formulations: Types and Delivery01:27

Insulin Formulations: Types and Delivery

Insulin preparations are categorized by their duration of action into short-acting and long-acting types. Two strategies are used to modify insulin's absorption and pharmacokinetic profile: slowing the absorption post-subcutaneous injection, or altering human insulin's amino acid sequence or protein structure. These changes retain the insulin's ability to bind to the insulin receptor, but alter its behavior in solution or after injection.
Short-acting insulins are divided into rapid-acting...
One-Compartment Model: IV Infusion01:09

One-Compartment Model: IV Infusion

Intravenous (IV) infusion is often utilized when continuous and controlled drug delivery is necessary, such as during surgery or in the treatment of chronic diseases. This method offers numerous advantages, including immediate drug action, precise control over dosage, and bypassing the first-pass metabolism.
The one-compartment model for IV infusion uses mathematical equations to describe the rate of change in drug quantity in the body. At steady-state or infusion equilibrium, the drug input...
Two-Compartment Open Model: IV Infusion01:15

Two-Compartment Open Model: IV Infusion

A two-compartment model is a vital tool in pharmacokinetics, providing an essential understanding of drug behavior, especially for those administered via zero-order intravenous infusion. This model outlines two compartments: the central compartment, where elimination occurs, and the peripheral compartment.
The model illustrates the decrease in plasma drug concentration from the central compartment with a specific equation. It shows that under steady-state conditions, the drug's input rate...
Pharmaceutical Poisoning: Potential Scenarios01:26

Pharmaceutical Poisoning: Potential Scenarios

Pharmaceutical poisoning can occur through various channels, impacting an estimated 2 million hospitalized patients in the U.S. annually with serious adverse drug responses. These scenarios encompass both therapeutic uses, such as drug toxicity, where even standard dosages can lead to severe central nervous system depression, and non-therapeutic exposures, including accidental ingestion by children, and environmental and occupational exposures.Unintentional poisonings often involve exploratory...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

The physiology of saltwater acclimation in large juvenile Atlantic salmon Salmo salar.

Journal of fish biology·2018
Same author

Medical device risk management and safety cases.

Biomedical instrumentation & technology·2015
Same author

Evaluation of the giant reed (Arundo donax) in horizontal subsurface flow wetlands for the treatment of dairy processing factory wastewater.

Environmental science and pollution research international·2012
Same author

Generic safety requirements for developing safe insulin pump software.

Journal of diabetes science and technology·2012
Same author

Design considerations for medical devices in the home environment.

Biomedical instrumentation & technology·2011
Same author

Evaluation of the giant reed (Arundo donax) in horizontal subsurface flow wetlands for the treatment of recirculating aquaculture system effluent.

Environmental science and pollution research international·2011

Related Experiment Video

Updated: Jun 14, 2026

Improving IV Insulin Administration in a Community Hospital
12:08

Improving IV Insulin Administration in a Community Hospital

Published on: June 11, 2012

A hazard analysis for a generic insulin infusion pump.

Yi Zhang1, Paul L Jones, Raoul Jetley

  • 1Office of Science and Engineering Laboratories, Center for Device and Radiological Health, US Food and Drug Administration, Silver Spring, Maryland 20993-002 , USA. Yi.Zhang2@fda.hhs.gov

Journal of Diabetes Science and Technology
|March 24, 2010
PubMed
Summary

Researchers developed a generic insulin infusion pump (GIIP) model to enhance medical device software quality. This model provides a foundation for a safety standard to improve insulin pump reliability and user safety.

More Related Videos

Subcutaneous Angiotensin II Infusion using Osmotic Pumps Induces Aortic Aneurysms in Mice
07:21

Subcutaneous Angiotensin II Infusion using Osmotic Pumps Induces Aortic Aneurysms in Mice

Published on: September 28, 2015

Studying the Hypothalamic Insulin Signal to Peripheral Glucose Intolerance with a Continuous Drug Infusion System into the Mouse Brain
08:32

Studying the Hypothalamic Insulin Signal to Peripheral Glucose Intolerance with a Continuous Drug Infusion System into the Mouse Brain

Published on: January 4, 2018

Related Experiment Videos

Last Updated: Jun 14, 2026

Improving IV Insulin Administration in a Community Hospital
12:08

Improving IV Insulin Administration in a Community Hospital

Published on: June 11, 2012

Subcutaneous Angiotensin II Infusion using Osmotic Pumps Induces Aortic Aneurysms in Mice
07:21

Subcutaneous Angiotensin II Infusion using Osmotic Pumps Induces Aortic Aneurysms in Mice

Published on: September 28, 2015

Studying the Hypothalamic Insulin Signal to Peripheral Glucose Intolerance with a Continuous Drug Infusion System into the Mouse Brain
08:32

Studying the Hypothalamic Insulin Signal to Peripheral Glucose Intolerance with a Continuous Drug Infusion System into the Mouse Brain

Published on: January 4, 2018

Area of Science:

  • Biomedical Engineering
  • Medical Device Software Quality
  • Regulatory Science

Background:

  • Exploration of model-based engineering to enhance medical device software quality.
  • Insulin pumps selected due to research complexity and regulatory challenges.
  • Focus on improving the safety and reliability of insulin pump technology.

Purpose of the Study:

  • To establish a generic insulin infusion pump (GIIP) model architecture.
  • To develop a comprehensive hazard analysis for insulin pumps.
  • To lay the groundwork for an insulin pump safety reference standard.

Main Methods:

  • Utilized a highly abstract generic insulin infusion pump (GIIP) model.
  • Identified hazards through expert consultation, standards review, and adverse event reports.
  • Consolidated hazard information for community analysis and discussion.

Main Results:

  • Established a generic insulin infusion pump model architecture.
  • Presented a comprehensive hazard analysis document corresponding to the GIIP model.
  • Facilitated a structured approach to understanding insulin pump risks.

Conclusions:

  • This work initiates an insulin pump safety reference standard for future designs.
  • The GIIP model aims to ensure a basic level of safety for insulin pumps.
  • Further engagement with the diabetes community is crucial for refining the safety modeling process.