Related Experiment Video
Updated: Jun 14, 2026

08:54
In Vivo Assessment of Alveolar Macrophage Efferocytosis Following Ozone Exposure
Published on: October 22, 2019
Ozone profiling from backscattered UV radiance measurements: a new procedure
Applied Optics
|March 24, 2010
Summary
This study introduces a new data analysis method for stratospheric ozone profiling using satellite UV radiation measurements. The technique provides accurate ozone mixing ratio profiles with error bars, improving atmospheric analysis.
Area of Science:
- Atmospheric Science
- Remote Sensing
- Spectroscopy
Background:
- Stratospheric ozone plays a crucial role in Earth's atmosphere.
- Accurate ozone profiling is essential for climate and atmospheric research.
- Previous methods lacked combined features for comprehensive ozone analysis.
Purpose of the Study:
- To develop and present an advanced data analysis technique for stratospheric ozone measurement.
- To support ongoing stratospheric ozone measurement and profiling programs.
- To provide ozone mixing ratio profiles with associated error bars.
Main Methods:
- Utilizes nonlinear optimal estimation principles.
- Analyzes solar backscattered ultraviolet (UV) radiation data from spacecraft.
- Incorporates iteration on both radiation and total ozone measurements.
Main Results:
- Generates detailed ozone mixing ratio profiles across the atmosphere.
- Provides error bars for each profile, indicating measurement uncertainty.
- Offers a novel technique with combined desirable features not previously available.
Conclusions:
- The developed technique offers significant improvements for stratospheric ozone profiling.
- It enhances the accuracy and reliability of atmospheric ozone measurements.
- This method supports advanced research in atmospheric science and climate monitoring.
Related Concept Videos
Ultraviolet and Visible (UV–Vis) Spectroscopy: Overview
Ultraviolet–visible (UV–visible or UV–Vis) spectroscopy is an analytical technique that investigates the interaction between matter and UV–Vis light within the electromagnetic spectrum. This method is widely used for its versatility, simplicity, and relatively quick data acquisition, making it valuable for both qualitative and quantitative analysis. When UV–Vis radiation passes through a material, molecules absorb light depending on the energy required for electronic transitions. As a result...
UV–Vis Spectrometers
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
UV–Vis Spectroscopy: Woodward–Fieser Rules
UV–Visible absorption spectra of conjugated dienes arise from the lowest energy π → π* transitions. The light-absorbing part of the molecule is called the chromophore, and the substituents directly attached to the chromophore are called auxochromes. A strong correlation exists between the absorption maxima, λmax, and the structure of a conjugated π system. The Woodward–Fieser rules predict the value of λmax for a given structure by adding the contributions...
UV–Vis Spectrum
When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar absorptivity (ε) or log ε on the y-axis (ordinate)...
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar absorptivity (ε) or log ε on the y-axis (ordinate)...
UV–Vis Spectroscopy: Beer–Lambert Law
The Beer-Lambert law describes the relationship between absorbance and concentration, which combines the principles established by scientists Johann Heinrich Lambert and August Beer. Lambert's law states that when light passes through a medium, the loss in intensity is directly proportional to the original intensity and the path length of the light. Beer's law proposed that the transmittance of a solution remains constant if the product of concentration and path length is constant. The modern...
Attenuated Total Reflectance (ATR) Infrared Spectroscopy: Overview
Attenuated total reflectance (ATR) infrared spectroscopy is a powerful analytical technique used to study the composition of materials. It is widely employed in chemistry, materials science, forensic science, and other fields where sample characterization is required. ATR has several advantages over traditional transmission IR spectroscopy, including the requirement of little to no sample preparation and the ability to analyze a wide range of samples.
The ATR process begins by directing a beam...
The ATR process begins by directing a beam...