An Anaerobic Biosensor Assay for the Detection of Mercury and Cadmium
Published on: December 17, 2018
Detection of mercury in fish organs with a two-photon fluorescent probe
Chang Su Lim1, Dong Won Kang, Yu Shun Tian
1Department of Chemistry, Korea University, 1-Anamdong, Seoul, Korea.
Abstract:
We report a two-photon fluorescent probe (AHg1) that can be excited by 780 nm femto-second pulses, shows high photostability and negligible toxicity, and can visualize the site of Hg(2+) accumulation, but can also estimate trace amounts of mercury ions in fresh fish organs by two-photon microscopy.
Related Concept Videos
Labeling DNA Probes
DNA probes are fragments of DNA labeled with a reporter tag to enable their detection or purification. The resulting labeled DNA probes can then hybridize to target nucleic acid sequences through complementary base-pairing, and may be used to recover or identify these regions.
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
FISH - Fluorescent In-situ Hybridization
Fluorescence in situ hybridization, or FISH, was developed in the early 1980s and has quickly become one of the most widely used techniques in cytogenetics. Labeled probes are used to bind complementary DNA or RNA sequences on a chromosome or in a region within a cell. Earlier, the probes could only be obtained by cloning or reverse transcription of a DNA template. Currently, the probe oligonucleotides can be synthesized synthetically. Additionally, with the advancement of optical techniques,...
Fluorescence and Phosphorescence: Instrumentation
Fluorometers and spectrofluorometers are two types of instruments used for measuring molecular fluorescence. These instruments differ in how they select excitation and emission wavelengths and the type of light sources they utilize. Fluorometers use absorption interference filters to choose excitation and emission wavelengths. The excitation source in a fluorometer is typically a low-pressure mercury vapor lamp that emits intense lines distributed throughout the ultraviolet and visible regions.
Photoluminescence: Applications
Photoluminescence offers a wide range of applications due to its inherent sensitivity and selectivity. This technique allows for both direct and indirect analyses of the analyte. Direct quantitative analysis is possible when the analyte exhibits a favorable quantum yield for fluorescence or phosphorescence. However, an indirect analysis may be feasible if the analyte is not fluorescent or phosphorescent, or if the quantum yield is unfavorable. Indirect methods include reacting the analyte with...