Related Experiment Video
Updated: Jun 14, 2026

In Situ Soil Moisture Sensors in Undisturbed Soils
Published on: November 18, 2022
Using air-coupled sensors to determine the depth of a surface-breaking crack in concrete
1Department of Civil, Architectural, and Environmental Engineering, The University of Texas, Austin, Texas 78712-0273, USA.
Abstract:
Previous studies showed that the surface wave transmission coefficient across a surface-breaking crack in concrete can be used to estimate the crack depth. However, inconsistencies in the surface wave transmission measurements limit the test accuracy and application of this technique. The inconsistencies come from near-field scattering by the crack tip and inconsistent sensor coupling conditions on rough concrete surfaces. This study first investigates the near-field size based on numerical analyses, and then suggests that reliable surface wave transmission should be measured in the far field. Based on the far-field measurement, the relationship between the surface wave transmission ratio and the normalized crack depth (crack depth/wavelength) is obtained. In the experimental study, the air-coupled sensing method is proposed as a solution to the sensor coupling problem. Owing to the non-contact feature, the air-coupled sensing method not only improves testing speed but also enables more consistent signal measurement. The experimental study using air-coupled sensors shows good agreement with the results of numerical simulation and analytic solution.
Related Concept Videos
Measurement of Air Content in Concrete
The pressure method,...
Microcracking in Concrete
Types of Non-structural Cracks in Concrete
Plastic shrinkage cracks typically form within hours after the concrete is poured. The concrete's surface dries faster than the bottom, creating tensile stress that the still-plastic concrete cannot withstand, leading to diagonal or randomly patterned cracks on the concrete surface.
Plastic...
Non-destructive Tests for Concrete Strength
Abrasion Resistance of Concrete
One such test is the revolving disc test, where three plates...
Frost Action on Concrete
This freeze-thaw cycle primarily causes surface scaling, where...