Application of a solid electrolyte CO(2) sensor for the analysis of standard volatile organic compound gases
Tetsuya Kida1, Min-Hyun Seo, Shotaro Kishi
1Department of Energy and Material Sciences, Faculty of Engineering Sciences, Kyushu University, Kasuga-koen, Kasuga, Fukuoka, 816-8580, Japan. kida@mm.kyushu-u.ac.jp
Abstract:
Preparation and analysis of standard VOC (volatile organic compound) gases are needed when developing and evaluating the performance of analytical methods or instruments to detect VOCs. In this study, we designed and developed a simple system for the analysis of VOCs based on their decomposition into CO(2) by a combustion catalyst and their subsequent detection using a solid electrolyte CO(2) sensor. In this sensor, NASICON (Na(3)Si(2)Zr(2)PO(4); Na(+) conductor) and binary carbonate (Li(2)CO(3)-BaCO(3)) were used as the solid electrolyte and the sensing layer, respectively. This developed system proved to be effective in determining the concentrations of standard gases, including VOCs (ethanol, formaldehyde, and toluene), CO, and hydrocarbons in parts per million concentrations (10-500 ppm). The system also could continuously monitor the variations in ethanol vapors prepared by a diffusion method where liquid ethanol was heated at 25 and 50 degrees C. The advantages and limitations of our developed analytical system are also discussed.
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
08:10Fizzy Extraction of Volatile Organic Compounds Combined with Atmospheric Pressure Chemical Ionization Quadrupole Mass Spectrometry
Published on: July 14, 2017
Related Concept Videos
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Volatilization
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Controlled-Potential Coulometry: Electrolytic Methods
The chosen potential ensures...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.