Observations on maximum entropy processing of MR images.

P R Moran1

  • 1Department of Radiology, Wake Forest University, Bowman Gray School of Medicine, Winston Salem, North Carolina 27103.

Magnetic Resonance Imaging
|January 1, 1991
PubMed
Summary

Maximum Entropy (MAXENT) criteria show improved performance in MR image processing by distinguishing between pixel-location and pixel-value data transmission. This modification enhances data processing for visual display applications, such as lumbar spine scans.

Related Concept Videos

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Velocity sensitivity of slice-selective excitation.

Magnetic resonance imaging·1998
Same author

Magnetization transfer or spin-lock? An investigation of off-resonance saturation pulse imaging with varying frequency offsets.

AJNR. American journal of neuroradiology·1996
Same author

Near-resonance spin-lock contrast.

Magnetic resonance imaging·1995
Same author

Effects of intravoxel velocity distributions on the accuracy of the phase-mapping method in phase-contrast MR angiography.

Journal of magnetic resonance imaging : JMRI·1994
Same author

Flow field mapping by multi-zone adiabatic passage excitation.

Magnetic resonance imaging·1993
Same author

Experiments for two MR imaging theories of motion phase sensitivity.

Radiology·1991

Area of Science:

  • Medical Imaging
  • Image Processing
  • Information Theory

Background:

  • Previous Maximum Entropy (MAXENT) criteria demonstrated suboptimal performance in Magnetic Resonance (MR) image processing.
  • Existing MAXENT formulations intermixed two distinct data transmission applications: pixel-location and pixel-value data.
  • The distinction between transmitted variables (pixel-locations vs. pixel-values) was not adequately addressed in prior literature.

Purpose of the Study:

  • To differentiate between the two "data transmission" applications within MR image processing.
  • To modify MAXENT criteria by focusing on pixel-value information entropy for improved MR image processing.
  • To demonstrate the successful application of modified MAXENT criteria in restoring MR image visualization.

Main Methods:

Related Experiment Videos

  • Distinguished between pixel-location entropy and pixel-value information entropy in MR image data.
  • Modified MAXENT criteria to specifically utilize pixel-value intensities for data processing.
  • Applied the modified MAXENT criteria to restore display visualization from nonuniform surface coils in lumbar spine scans.

Main Results:

  • The modified MAXENT criteria, utilizing pixel-value information entropy, yielded successful data processing results.
  • Effective restoration of display visualization was achieved for lumbar spine scans acquired with nonuniform surface coils.
  • The study confirmed the enhanced utility of MAXENT in specific MR image processing contexts.

Conclusions:

  • Revising MAXENT criteria to account for pixel-value information entropy significantly improves MR image processing performance.
  • The distinction between data transmission types is crucial for successful application of MAXENT in medical imaging.
  • Modified MAXENT provides a valuable tool for enhancing visualization in challenging MR imaging scenarios, exemplified by lumbar spine scans.