Related Experiment Video
Updated: Jun 14, 2026

Real-Time Assessment of Spinal Cord Microperfusion in a Porcine Model of Ischemia/Reperfusion
Published on: December 10, 2020
Locating the right phrenic nerve by imaging the right pericardiophrenic artery with computerized tomographic
Rodney Horton1, Luigi Di Biase, Vivek Reddy
1Texas Cardiac Arrhythmia Institute, St. Davids Medical Center, Austin, Texas, USA.
Background:
Phrenic nerve (PN) injury, a known complication of radiofrequency (RF) catheter ablation of atrial fibrillation (AF), has been more commonly reported with balloon-based pulmonary vein isolation.
Objective:
We present a novel approach to locating the PN and predicting patients at higher risk of this complication.
Methods:
The study included 2 groups of patients. In the first group of 71 patients, computerized tomographic angiography (CTA) with 3-dimensional reconstruction of the left atrium (LA) was obtained prior to an RF ablation procedure. The location of the right pericardiophrenic artery (RPA) was identified on the axial CTA images, and the artery distance to the right superior pulmonary vein (RSPV) ostium was measured in the 3-dimensional image. During ablation, the location of the right PN was identified by pacing maneuvers. The distance to the ostium of the RSPV was measured by venography and compared with the CTA artery measurement. In the second group, CTA imaging from 37 subjects who were enrolled in 3 investigational balloon ablation trials were analyzed using the same PN location technique and compared against the clinical outcomes. In this analysis, the CTA segmentation and PN location was performed in a blinded fashion as to any clinical evidence of PN injury.
Results:
The mean measurement difference between PN capture and imaged RPA was 0.8 mm (P = .539). In all cases, the imaged RPA could reliably identify the approximate location of the right PN (R-square 0.984, P < .001). Moreover, this analysis suggests that a PN location within 10 mm of the RSPV poses a higher risk of PN injury using these balloon ablation devices.
Conclusion:
Imaging the right pericardiophrenic artery can reliably locate the right phrenic nerve. This technique might identify anatomy more vulnerable to phrenic nerve injury using balloon-based ablation systems.
More Related Videos
08:00Reduction of Iatrogenic Atrial Septal Defects with an Anterior and Inferior Transseptal Puncture Site when Operating the Cryoballoon Ablation Catheter
Published on: June 15, 2015
08:43Chronic Ovine Model of Right Ventricular Failure and Functional Tricuspid Regurgitation
Published on: March 17, 2023
Related Concept Videos
Cardiac Catheterization II: Right Heart Catheterization
Cardiac Catheterization III: Left Heart Catheterization
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Imaging Studies for Cardiovascular System III: X-Ray
Definition and Purpose
An X-ray, or radiograph, is a non-invasive method that uses ionizing radiation to take images of internal structures. It is mainly used in cardiac imaging to examine the heart, lungs, and major blood vessels, aiming to identify abnormalities in the heart's size, shape, and position, such as heart failure, congenital defects, and vascular...