A proposed method of logarithmic transformation of optical coherence tomography data for use in clinical research
Frederick L Ferris1, Kellee M Miller, Adam R Glassman
1National Eye Institute, National Institute of Health, Bethesda, Maryland, USA.
Purpose:
To evaluate a logarithmic transformation of retinal thickness measurements from optical coherence tomography as a new approach to assess clinically meaningful changes in retinal thickness.
Design:
Methodologic, evidence-based review.
Methods:
Standard published approaches for assessing change in retinal thickness over time, as measured by optical coherence tomography (OCT), were compared with a new approach based on a logarithmic transformation of the retinal thickness data. Comparative examples were derived using published data from a clinical trial comparing intravitreal corticosteroid injections for diabetic macular edema with standard laser treatment.
Main Outcome Measures:
Comparative examples using Diabetic Retinopathy Clinical Research Network data.
Results:
Logarithmic transformation of retinal thickness data results in a more normalized distribution of OCT data and allows for data analyses assessing proportionate changes in retinal thickness during follow-up.
Conclusions:
For analysis of grouped data, a logarithmic transformation of the OCT retinal thickness measurements (logOCT) provides several analytic advantages. Distributions of retinal thickness in groups of eyes with diabetic macular edema, and many other causes of macular thickening, tend to be skewed to the right; the logOCT transformation tends to normalize these distributions, which has value for statistical comparisons. For assessing whether the observed OCT change in a patient is real (and not due to testing variability), a 1-step log scale change exceeds the measurement error for all degrees of retinal thickness in current instruments. In addition, this log scale is similar to the logarithm of the minimum angle of resolution (logMAR) scale used for visual acuity. Steps on the log scale for change in thickness seem to be better related to clinical importance than the actual change in microns because each step on the log scale is the same proportionate change in thickness, with a 3-step change equaling a halving or doubling of thickness, regardless of the baseline value. Transformation of OCT retinal thickness data to logOCT may assist in the assessment of clinically meaningful changes in retinal thickness just as use of the logMAR scale has helped to assess clinically meaningful changes in visual acuity.
More Related Videos
15:18Near Infrared Optical Projection Tomography for Assessments of β-cell Mass Distribution in Diabetes Research
Published on: January 12, 2013
08:50Longitudinal Morphological and Physiological Monitoring of Three-dimensional Tumor Spheroids Using Optical Coherence Tomography
Published on: February 9, 2019
Related Concept Videos
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...