High Speed Sub-GHz Spectrometer for Brillouin Scattering Analysis
Published on: December 22, 2015
Spectral measurements of stack effluents using a double-beam interferometer with background suppression.
This study used a mobile double-beam interferometer to measure stack effluent emissions, offering real-time background suppression for accurate field analysis. The technology enables effective environmental monitoring and data comparison, as demonstrated with incinerator emissions.
Area of Science:
- Environmental Science
- Analytical Chemistry
- Spectroscopy
Background:
- Industrial and municipal emissions require accurate monitoring.
- Real-time analysis of effluent spectra is crucial for environmental compliance.
- Traditional methods may lack the sensitivity or speed for effective background suppression.
Purpose of the Study:
- To evaluate a mobile double-beam interferometer for measuring stack effluent emission spectra.
- To demonstrate the system's capability for real-time background suppression in field settings.
- To analyze and compare measured spectra with synthetic models.
Main Methods:
- Utilized a double-beam interferometer installed in a mobile van.
- Conducted field site measurements of effluents from four selected stacks.
- Employed real-time graphical data display for immediate analysis.
- Compared a municipal incinerator spectrum with a FASCODE generated synthetic spectrum.
Main Results:
- The double-beam interferometer provided effective real-time background suppression.
- Field site measurements and near real-time data display were successfully achieved.
- Analysis of selected spectra, including comparison with synthetic data, was performed.
Conclusions:
- Double-beam interferometry is a viable technique for mobile, real-time effluent emission analysis.
- The system offers advantages in background suppression for environmental monitoring.
- The methodology supports accurate spectral analysis and comparison with theoretical models.
Related Concept Videos
Atomic Emission Spectroscopy: Interference
Atomic Absorption Spectroscopy: Interference
Spectral interference occurs when signals from other elements or molecules overlap with the analyte signal, falsely elevating or masking the analyte's absorbance. This interference can be corrected using Zeeman,...
Inductively Coupled Plasma Atomic Emission Spectroscopy: Instrumentation
There are three main types of inductively coupled plasma atomic emission spectroscopy (ICP-AES) instruments: sequential, simultaneous multichannel, and Fourier transform instruments, with the latter being less commonly used.
IR Spectrometers
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Atomic Emission Spectroscopy: Instrumentation