Pulse Wave Velocity Testing in the Baltimore Longitudinal Study of Aging
Published on: February 7, 2014
Arterial pulse wave velocity measurement: different techniques, similar results--implications for medical devices
Ashis Mookerjee1, Ahmed M Al-Jumaily, Andrew Lowe
1Institute of Biomedical Technologies, AUT University, Private Bag 92006, Auckland, New Zealand.
Abstract:
Different characteristic points used for the evaluation of pulse wave velocity (PWV) give significantly different results. Hence, the accuracy of using these points is questionable. There is need for quantitative comparison of different techniques to determine PWV. Previous studies aimed at comparing different PWV measurement techniques have been noted, however, on a limited number of smaller animals (mice, dogs, etc.). This simulation-based study aims to compare different techniques for PWV measurement in a large representative human population. A computer model is developed for simulating the pressure wave propagation between the carotid and femoral arteries. Using relationships observed in clinical trials, the model input parameters for a statistically representative population are expressed in terms of a person's age, gender and height. The model is used to calculate the carotid-femoral pressure ratio for different individuals, which is then parameterised into a number of features, and the equivalent propagation time is calculated using the phase-slope method. Using this time, the apparent phase velocity is determined and compared with PWV determined by the foot-to-foot technique. The two velocities compare well with a difference of 0.0059±0.0904 m/s. An averaging criterion for the calculation of apparent phase velocity has been tested and shown to give good estimates compared to the foot-to-foot technique. As it does not involve the identification of characteristic points on the measured pressure waves, the phase-slope method is more suitable for implementation in PWV monitors.
Related Concept Videos
Pulse
The pulse serves as a clinical indicator...
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Special considerations while measuring pulse
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps: