Advancements and challenges in blood pressure monitoring using pulse wave propagation: a comprehensive review and ISO
1AUT Institute of Biomedical Technologies (IBTec), Auckland University of Technology, Auckland, New Zealand. yyu@aut.ac.nz.
Abstract:
Cardiovascular diseases, particularly hypertension, remain a major global health burden, highlighting the need for accurate and accessible blood pressure (BP) monitoring. Cuffless BP measurement (BPM) based on pulse wave propagation methods (PWPM), including pulse arrival time (PAT), pulse transit time (PTT), and pulse wave velocity (PWV), has attracted increasing research interest. This review comprises two components. First, a narrative review of studies published up to June 2025 examines sensing technologies, mathematical models, and validation protocols used in PWPM-based BPM. Second, a statistical re-evaluation of 22 studies published between 2015 and 2025 was conducted using the Credence of Device Acceptability (CDA) and the Probability of Tolerable Error (PTE), grounded in the statistical principles of ISO 81060-2. Accuracy varied widely across physiological conditions, sensing technologies, and study designs, with no single approach demonstrating consistent superiority. The re-evaluation provided a more stringent assessment of performance: only five studies achieved CDA values exceeding 0.95 for both systolic and diastolic BP. Overall, diastolic BP estimation demonstrated superior accuracy compared with systolic BP. Incorporating physiological indices such as arterial compliance and sympathetic activity may improve the robustness and accuracy of BP estimation models. While machine learning shows promise for enhanced feature extraction, calibration tolerance and real-world reliability remain critical challenges. Importantly, the evaluation and development of cuffless BPM technologies should align with validation standards appropriate to the intended application. We recommend that future early-stage studies apply the CDA and PTE framework as supportive accuracy metrics to better assess methodological performance and inform device development and validation.
Related Concept Videos
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Errors occurring during blood pressure monitoring
Several factors...
Assessing Blood pressure using a doppler ultrasound
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Assessment of blood pressure in brachial artery(two-step method)