Related Experiment Video
Updated: Jun 14, 2026

A Rapidly Incremented Tethered-Swimming Maximal Protocol for Cardiorespiratory Assessment of Swimmers
Published on: January 28, 2020
Examining the accumulated oxygen deficit method in breaststroke swimming
Victor Machado Reis1, Daniel Almeida Marinho, Fernando Policarpo Barbosa
1Department of Sport Sciences, Exercise and Health, University of Trás-os-Montes and Alto Douro, Rua Dr. Manuel Cardona/CIFOP, 5000-558, Vila Real, Portugal. vreis@utad.pt
Abstract:
The present study investigated the accumulated oxygen deficit (AOD) method in breaststroke swimming with the aims to assess the reliability of the oxygen uptake/swimming velocity regression line and to quantify the precision of the AOD. Sixteen male swimmers performed two swimming tests in different days, with a 24-h recovery between tests: a graded swimming test and an all-out test. The all-out test was performed in one of two distances: 100 m (n = 7) or 200 m (n = 9). Through all testing, expired gases were collected breath by breath and analysed with a K4b2 Gas Analyser (Cosmed, Rome, Italy) connected to an AquaTrainer Valve (Cosmed, Rome, Italy). The standard error of the regression lines was approximately 5-6 ml kg(-1) min(-1) and the regressions allowed an extrapolation of the energy cost to higher intensities with a standard error of the predicted value that was lower in the 200-m bout (approximately 3.5 ml kg(-1) min(-1)) comparatively to the 100-m bout (approximately 6 ml kg(-1) min(-1)). The AOD imprecision was calculated as the square root of the sum of the oxygen uptake measurement error and the standard error of the predicted value for energy cost. AOD imprecision was smaller in the 200-m bout (approximately 9 ml kg(-1) min(-1)) comparatively to the 100-m bout (approximately 12 ml kg(-1) min(-1)). However, since the AOD values during the two distances were small, the AOD relative errors can be viewed as high. Additionally, the data variability was considerable (95% confidence intervals of the linear extrapolation larger than 20 ml kg(-1) min(-1)).
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.
Assessment of Diffusion and Perfusion
The Role of Diffusion in Respiration
Diffusion is the process by which molecules move from an area of higher concentration to an area of lower concentration. In the respiratory system, this principle...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Oxygen Transport in the Blood

