Direct aqueous injection with backflush thermal desorption for wastewater monitoring by online GC-MS
W Ziemer1, M Wortberg, C Eichberger
1BASF SE, Environmental Analytics and Water/Steam Monitoring, 67056 Ludwigshafen, Germany.
Abstract:
A gas chromatography-mass spectrometry system with a novel injector type, which is designed for direct aqueous injection of wastewater, is presented. The system is used for online monitoring of the influent of the wastewater treatment plant at BASF's main chemical production site in Ludwigshafen, Germany. The purpose of monitoring is to protect the biological treatment process and the receiving water body, the Rhine. The modular system is primarily based on commercial equipment, but utilizes a special injection system, which is connected to a Deans switch. The two-stage injector consists of a programmable temperature vaporizer (PTV) injector with a small volume insert for vaporization and a dual sorbent packed second PTV for analyte adsorption/desorption. The Deans switch allows a backflush/thermal desorption operation which enables the direct injection of filtered, crude wastewater. About 170 volatile and semivolatile compounds are calibrated with approximate detection limits of 1 mg/L, which are sufficient for the analysis of untreated wastewater. The quantitative results are transferred to a database which is connected to a process control system. If the wastewater does not meet the required specification, an alarm is generated and the wastewater is diverted into a storage basin. Special software programs and routines allow for reliable, unattended operation and remote instrument control. Data quality is automatically controlled in each run and through the daily analysis of quality control samples. The current design allows for analysis of volatile compounds, such as methanol, whereas an earlier injector setup restricted the range of analytes to less volatile compounds (of size C(4) or greater).
More Related Videos
07:57Quantitative Detection of Trace Explosive Vapors by Programmed Temperature Desorption Gas Chromatography-Electron Capture Detector
Published on: July 25, 2014
11:59Extraction and Detection of Geosmin and 2-Methylisoborneol in Water and Fish using High-Capacity Sorptive Extraction Probes and GC-MS
Published on: July 3, 2025
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall. The coating...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
High-Performance Liquid Chromatography: Types of Detectors