Related Experiment Video
Updated: Jun 14, 2026

Electrophoretic Crystallization of Ultrathin High-performance Metal-organic Framework Membranes
Published on: August 16, 2018
Fluoride-selective polymeric membrane electrodes based on Zr(IV)- and Al(III)-salen ionophores of various structures
Łukasz Górski1, Alexey Matusevich, Paweł Parzuchowski
1Warsaw University of Technology, Faculty of Chemistry, Department of Microbioanalytics, Noakowskiego 3, 00-664 Warsaw, Poland. lukegor@ch.pw.edu.pl
Abstract:
Al(III)- and Zr(IV)-salophens of novel structures were tested as anion-selective ionophores. It was shown that these compounds are highly selective to fluoride and give selectivity greatly deviating from classical Hofmeister pattern, when doped into the polymeric membrane of ion-selective electrode (ISE). The following selectivity sequence has been recorded for both ionophores: F(-) > ClO(4)(-) > SCN(-) > NO(3)(-) approximately Br(-) approximately Cl(-). The results of potentiometric and spectrophotometric measurements allow to conclude that the nature and structure of salophen ligands influence stability of ISE working parameters. An increase in salophen ligands lipophilicity results in prolongation of the ISE lifetime, most likely due to slower ionophore decomposition caused by the hydrolysis of imine bonds in salophen structure. Ion-selective electrodes (ISEs) with the most successful Al(III)-salophen exhibited a stable, fast and near-Nernstian fluoride response and a functional lifetime near 3 weeks and selectivity coefficients with log K(F(-), Y(-))(pot) as follows: -2.8 (Y(-)=Br(-)), -2.7 (Cl(-)), -2.8 (NO(3)(-)), -1.5 (SCN(-)), -1.3 (ClO(4)(-)), which is better than for other ones based on Zr(IV)- and Al(III)-salophens and salens described to date.
More Related Videos
08:06Merging Ion Concentration Polarization between Juxtaposed Ion Exchange Membranes to Block the Propagation of the Polarization Zone
Published on: February 23, 2017
08:03Multi-analyte Biochip (MAB) Based on All-solid-state Ion-selective Electrodes (ASSISE) for Physiological Research
Published on: April 18, 2013
Related Concept Videos
Potentiometry: Membrane Electrodes
Ionic Crystal Structures
Most monatomic ions behave as charged spheres, and their attraction for ions of opposite charge is the same in every direction. Consequently, stable structures for ionic compounds result (1) when ions of one charge are surrounded by as many ions as possible of the opposite...
Ion Exchange
Types of Reversible Electrodes
Electrochemical Systems
Ion-Exchange Chromatography