Related Experiment Video
Updated: Jun 14, 2026

International Expert Consensus and Recommendations for Neonatal Pneumothorax Ultrasound Diagnosis and Ultrasound-guided Thoracentesis Procedure
Published on: March 12, 2020
Pleural ultrasound compared with chest radiographic detection of pneumothorax resolution after drainage
Arnaud Galbois1, Hafid Ait-Oufella, Jean-Luc Baudel
1Université Pierre et Marie Curie, Service de Réanimation Médicale, Hôpital Saint-Antoine, AP-HP, Paris, France. galbois@gmail.com
Background:
Pleural ultrasonography (PU) is more sensitive than chest radiograph (CXR) for diagnosing pneumothorax and could be useful for detecting resolution of pneumothorax after drainage. The aim of this prospective double-blind observational study was to assess PU accuracy during pneumothorax follow-up after drainage.
Methods:
All patients hospitalized with pneumothorax requiring drainage were eligible. After drainage, residual pneumothorax was assessed by CXR and PU (1) 24 h after bubbling in the aspiration device had stopped, (2) 6 h after clamping the pleural catheter, and (3) 6 h after removing the pleural catheter. Pneumothorax indicated by PU but not CXR was confirmed by CT scan or by aspiration of > 10 mL of air.
Results:
Forty-four unilateral pneumothoraces were studied (primary spontaneous: 70.5%), and 162 pairs of examinations (CXR and PU) were performed. Twenty residual pneumothoraces were detected by both CXR and PU. Furthermore, PU suspected 14 pneumothoraces that were not identified by CXR; 13 were confirmed. All of these pneumothoraces resulted in therapeutic intervention. Thus, 39% (13/33) of the confirmed residual pneumothoraces were missed by CXR. In patients with primary spontaneous pneumothorax, the positive predictive value of PU for residual pneumothorax diagnosis was 100%; for other pneumothoraces, this value ranged from 90% in the absence of a lung point to 100% when a lung point was observed. PU results were obtained faster than results from CXR (35 +/- 34 min vs 71 +/- 56 min, P < .0001).
Conclusions:
The accuracy of PU is excellent for detecting residual pneumothorax during pneumothorax follow-up after drainage.
Related Concept Videos
Pneumothorax-II
Clinical Manifestations:
Endoscopic Studies II: Thoracocentesis
Description
Excess pleural fluid or air may accumulate in some respiratory disorders in the thoracic cavity. To treat pleural effusion, a physician conducts thoracentesis by carefully piercing the chest wall and entering...
Assessment of Respiration
Subjective Assessment: Nurses interview the patient to gather information directly during the subjective assessment. It includes questions about the individual's medical history, medications, and symptoms, focusing on past respiratory conditions like asthma or COPD,...
Physical Assessment of the Respiratory Tract III: Percussion
Percussion in Respiratory Assessment
Percussion evaluates underlying tissue composition with audible and tactile vibrations,...
Pneumothorax II: Pathophysiology
Chest Physiotherapy
Purpose
CPT is primarily used for patients with excessive bronchial secretions who have difficulty clearing...