Measuring Blood Pressure in Mice using Volume Pressure Recording, a Tail-cuff Method
Published on: May 15, 2009
[A calibrated method for blood pressure measurement based on volume pulse wave]
Ding Youde1, Deng Qinkai, Liang Feixue
1institute of Bioinformatics, School of Basic Medical Sciences, Southern Medical University, Guangzhou, 510515.
Abstract:
Physiology parameters measurement based on volume pulse wave is suitable for the monitoring blood pressure continuously. This paper described that the systolic blood pressure (SBP) and diastolic blood pressure (DBP) can be calibrated by measuring the pulse propagation time, just on one point of finger tip. The volume pulse wave was acquired by lighting the red and infrared LED alternately, and after signal processing, an accelerated pulse wave was obtained. Then by measuring the pulse wave propagation time between the progressive wave and reflected wave, we can find the relationship of the time and the blood pressure, and establish the related systolic blood pressure measurement equation. At the same time, based on the relationship between alternating current and direct current components in the volume pulse waveforms and through regression analysising, the relevant diastolic blood pressure measurement equation can be established. 33 clinical experimentation cases have been worked by dividing them into two groups: training group (18 cases) and control group (15 cases), by comparing with the measuring results of the OMRON electronic sphygmomanometer. The results indicated that the two methods had good coherence. The measurement described is simple and reliable, and may be served as a new method for noninvasively and continuously measurement of blood pressure.
Related Concept Videos
Equipments Used To Measure Blood Pressure
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure
Sites for measuring blood pressure
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessment of blood pressure in brachial artery(two-step method)
Assessment of blood pressure in brachial artery(one-step method)
Prepare for the Procedure:
Special considerations while measuring blood pressure
Monitoring Both Arms:
Monitoring BP in both arms during the initial assessment is advisable, as the systolic value may differ by five to ten mm Hg between arms. For subsequent BP assessments, use the arm with the higher reading.