Computed Tomography01:10

Computed Tomography

Tomography refers to imaging by sections. Computed tomography (CT) is a non-invasive imaging technique that uses computers to analyze several cross-sectional X-rays to reveal minute details about structures in the body.
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Reconstruction of Signal using Interpolation01:10

Reconstruction of Signal using Interpolation

Signal processing techniques are essential for accurately converting continuous signals to digital formats and vice versa. When a continuous signal is sampled with a period T, the resulting sampled signal exhibits replicas of the original spectrum in the frequency domain, spaced at intervals equal to the sampling frequency. To handle this sampled signal, a zero-order hold method can be applied, which creates a piecewise constant signal by retaining each sample's value until the next sampling...
Electron Microscope Tomography and Single-particle Reconstruction01:07

Electron Microscope Tomography and Single-particle Reconstruction

Transmission electron microscopy (TEM) can be used to determine the 3D structure of biological samples with the help of techniques such as electron microscope tomography and single-particle reconstruction. While single-particle reconstruction can examine macromolecules and macromolecular complexes in vitro conditions only, tomography permits the study of cell components or small cells in vivo.
Electron Tomography
Electron tomography can be performed either in TEM or STEM (scanning transmission...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

A vendor-neutral functional MRI acquisition protocol for multi-site studies.

Aperture neuro·2026
Same author

Reply: A Call for High-Level Evidence Before Routine Implementation of Posttreatment SPECT.

Journal of nuclear medicine : official publication, Society of Nuclear Medicine·2026
Same author

Phantom- and simulation-based validation of combined diffusion relaxometry in ex vivo ADRD white matter.

bioRxiv : the preprint server for biology·2026
Same author

Smooth optimization using global and local low-rank regularizers.

SIAM journal on imaging sciences·2026
Same author

Bilevel Optimized Implicit Neural Representation for Scan-Specific Accelerated MRI Reconstruction.

IEEE transactions on medical imaging·2026
Same author

Scan-Adaptive MRI Undersampling Using Neighbor-based Optimization (SUNO).

IEEE transactions on computational imaging·2026

Related Experiment Video

Updated: Jun 13, 2026

Hybrid µCT-FMT imaging and image analysis
13:45

Hybrid µCT-FMT imaging and image analysis

Published on: June 4, 2015

Regularized reconstruction in quantitative SPECT using CT side information from hybrid imaging.

Yuni K Dewaraja1, Kenneth F Koral, Jeffrey A Fessler

  • 1Department of Radiology, University of Michigan, Ann Arbor, MI 48109, USA. yuni@umich.edu

Physics in Medicine and Biology
|April 16, 2010
PubMed
Summary

A new penalized-likelihood (PL) SPECT reconstruction method using CT side information improves activity estimates in targets. This method enhances accuracy for both total activity and distribution, outperforming conventional OSEM and other regularization techniques.

More Related Videos

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
08:57

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT

Published on: June 21, 2011

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

Related Experiment Videos

Last Updated: Jun 13, 2026

Hybrid µCT-FMT imaging and image analysis
13:45

Hybrid µCT-FMT imaging and image analysis

Published on: June 4, 2015

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT
08:57

High Resolution 3D Imaging of Ex-Vivo Biological Samples by Micro CT

Published on: June 21, 2011

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph
05:32

Retrospective Cardiac Gating with A Prototype Small-Animal X-ray Computed Tomograph

Published on: February 21, 2025

Area of Science:

  • Nuclear Medicine
  • Medical Imaging
  • Image Reconstruction

Background:

  • Quantitative SPECT imaging is crucial for accurate dosimetry.
  • Conventional OSEM reconstruction can lead to blurring and edge artifacts.
  • Incorporating anatomical information can potentially improve SPECT reconstruction accuracy.

Purpose of the Study:

  • To implement and evaluate a penalized-likelihood (PL) SPECT reconstruction method using CT side information for improved quantitative accuracy.
  • To compare the performance of the novel PL-CT method against conventional OSEM and other regularization techniques.
  • To assess the impact of anatomical boundary information on estimating both total target activity and activity distribution.

Main Methods:

  • Developed a modified penalized-likelihood regularizer incorporating CT-derived anatomical boundary information (PL-CT).
  • Compared PL-CT reconstructions with non-CT penalized-likelihood methods and OSEM using simulations and I-131 phantom studies.
  • Evaluated reconstructions with uniform and non-uniform activity distributions, and with perfect/imperfect side information.

Main Results:

  • PL-CT reconstructions yielded more accurate activity estimates and profiles, closely matching ground truth for uniform targets.
  • PL-CT minimized edge artifacts seen with OSEM and blurring seen with non-CT regularization.
  • PL-CT reduced bias and RMSE compared to regularization without side information, and reduced RMSE/STD versus OSEM.

Conclusions:

  • CT side information in penalized-likelihood SPECT reconstruction significantly improves the accuracy of activity distribution estimation.
  • The PL-CT method achieves this improvement without compromising total target activity quantification.
  • This technique shows promise for hybrid SPECT/CT systems, particularly for applications like tumor dosimetry in radioimmunotherapy.