Related Experiment Video
Updated: Jun 13, 2026

Expedited Radiation Biodosimetry by Automated Dicentric Chromosome Identification (ADCI) and Dose Estimation
Published on: September 4, 2017
[Application of ICRP-103 in the calculation of effective dose associated to nuclear medicine tests]
M C Pujades Claumarchirant1, J F Martí Vidal, C Olivas Arroyo
1Servicio de Medicina Nuclear, Hospital Universitario La Fe, Valencia, España. mpuclau@gmail.com
Objective:
Re-evaluate the effective dose (E) of typical nuclear medicine procedures using the new ICRP-103 weighting factors and the latest dosimetry data and relate E with Background Equivalent Radiation Time (BERT).
Material And Methods:
Effective dose associated with radiopharmaceuticals and nuclear medicine procedures has been calculated for the following ages: adult, 15, 10, 5 and 1 year. Dosimetry data have been extracted from ICRP-106, ICRP-80, ICRP-53 and/or manufacturer's brochure.
Results:
The relationship of the data of effective dose associated with radiopharmaceuticals and explorations is shown. The new tissue weighting factors result in a decreased value of the effective dose, except in cases that particularly affect the breast, in which it increases. The effective dose associated with nuclear medicine procedures is in the range 0.1-60 mSv. BERT ranges from a few days to 20 years. The effective dose associated to tests in children is generally higher than the effective dose for an adult.
Conclusions:
The results shown in this paper are an updated collection of effective dose values for commonly used radiopharmaceuticals in nuclear medicine. Expressing the effective dose equivalent time in units of natural radiation helps to explain issues associated with radiation exposure to patients and healthcare personnel.
More Related Videos
06:20Irradiator Commissioning and Dosimetry for Assessment of LQ α and β Parameters, Radiation Dosing Schema, and in vivo Dose Deposition
Published on: March 11, 2021
07:31Characterization of Recombination Effects in a Liquid Ionization Chamber Used for the Dosimetry of a Radiosurgical Accelerator
Published on: May 9, 2014
Related Concept Videos
Biological Effects of Radiation
Radiological Investigation I: X-ray and CT
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...
Types of Biopharmaceutical Studies: Controlled and Non-Controlled Approaches
Non-controlled studies, commonly employed for initial exploration, lack a control group, rendering them susceptible to biases and external influences. In contrast, controlled...