Bis(isovalerylacetone)ethylenediimine nickel(II) as mixed stationary phase for gas chromatography
A J Laghari1, M Y Khuhawar, Zeenat M Ali
1Dr. M.A. Kazi Institute of Chemistry, University of Sindh, Jamshoro, Pakistan.
Abstract:
Bis(isovalerylacetone)ethylenediimine Nickel (II) (IVA(2)enNi) was examined as a mixed stationary phase with OV1 on Chromosorb G/NAW 60-80 mesh size for gas chromatography (GC) separation of aromatic hydrocarbons, heteroaromatics, alcohols, aldehydes, ketones, esters, nitro-, and amino compounds. Forty-six compounds were examined, and the GC results were compared with those obtained with 3% OV1 on Chromosorb G/NAW 60-80 mesh size under similar operating conditions. Improved resolutions, peak asymmetry, number of theoretical plates, and Kovats indices were obtained on the mixed stationary phase 3% OV1 + 5% IVA(2)enNi (w/w) compared to 3% OV1 column. The stability constant (K(m)), enthalpies (DeltaH), entropies (DeltaS), and Gibbs free energies (DeltaG) of the GC elution on column (2 m x 3 mm i.d.) packed with 3% OV1 + 5% IVA(2)enNi (w/w) on Chromosorb have been calculated. Donor-acceptor complexation in the gas phase indicated by the negative values of enthalpy (-DeltaH) were within 9.4-12.38 Kcal/mol, and Gibbs free energy (-DeltaG) ranged from 1.48 to 4.24 Kcal/mol. The retention time transformation on both the phases were calculated. The obtained ratios from the stationary phases 3% OV1 and 3% OV1 + 5% IVA(2)enNi (w/w) were plotted on the x-axis and y-axis, respectively. Two-dimensional chromatographic plots for alkanes, aromatics, heteroaromatics, ketones, alcohols, esters, and nitro compounds were obtained with coefficient of determination within 0.4934 and 0.9617, which is indicative of some different kinds of interaction of two stationary phases with the solutes.
Related Concept Videos
Gas Chromatography: Types of Columns and Stationary Phases
For an analyte to remain on the column for a sufficient amount of time, it must exhibit some level of compatibility (or...
Precipitation Gravimetry
In determining nickel by gravimetric analysis, a precipitant of ethanolic dimethylglyoxime is added to a hot nickel salt solution. This is quickly followed by the dropwise addition of dilute ammonia solution until precipitation occurs. A...
Ion-Exchange Chromatography
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a column.
Gas Chromatography: Types of Detectors-II