Related Experiment Video
Updated: Jun 13, 2026

Time-lapse Fluorescence Imaging of Arabidopsis Root Growth with Rapid Manipulation of The Root Environment Using The RootChip
Published on: July 7, 2012
Microleakage of various root filling systems by glucose filtration analysis
Meriç Karapinar-Kazandağ1, Jale Tanalp, Omer Faruk Bayrak
1Department of Endodontics, Faculty of Dentistry, Yeditepe University, Istanbul, Turkey. meric.karapinar@yeditepe.edu.tr
Objective:
The aim of this study was to evaluate the microleakage of Resilon + Epiphany, EndoRez, Activ GP, and conventional AH Plus + gutta-percha technique using the glucose filtration model.
Study Design:
One hundred twenty maxillary incisors were divided into 5 experimental and 2 control groups. After root canal shaping, the experimental groups were filled with AH Plus + gutta-percha (lateral compaction), Resilon + Epiphany (lateral compaction), AH Plus + Protaper's proprietory cone, EndoRez + sealer, or Activ GP + sealer). The specimens were mounted on a glucose model and samples were taken for 3 weeks for leakage measurement.
Results:
No statistically significant difference was observed between the leakage of all groups at the 3 testing periods (P > .05).
Conclusion:
The filling materials with the monoblock concept do not seem to be superior to the conventional AH Plus + gutta-percha system regarding microleakage.