A retrospective cohort study of the BioPro hemiarthroplasty prosthesis

Christine C Salonga1, David C Novicki, Martin M Pressman

  • 1Podiatric Surgery, Yale New Haven Hospital, New Haven, CT 06511, USA.

Insights

First metatarsophalangeal joint hemiarthroplasty using the BioPro Hemi Implant improved joint motion and patient satisfaction. This procedure offers a useful option for treating first metatarsophalangeal joint degeneration with a low complication rate.

Area of Science:

  • Orthopedic Surgery
  • Podiatric Surgery
  • Biomedical Engineering

Background:

  • First metatarsophalangeal (MTP) joint degeneration is a common condition causing pain and functional limitation.
  • Hemiarthroplasty is a surgical option for MTP joint arthritis, aiming to preserve joint function.
  • The BioPro Hemi Implant is one such device used for MTP joint hemiarthroplasty.

Purpose of the Study:

  • To evaluate the clinical outcomes of first metatarsophalangeal joint hemiarthroplasty using the BioPro Hemi Implant.
  • To assess the impact of the procedure on joint range of motion, radiographic parameters, and patient-reported outcomes.
  • To determine the complication rate associated with this specific hemiarthroplasty technique.

Main Methods:

  • Retrospective review of 79 procedures in 76 patients who underwent first MTP joint hemiarthroplasty with the BioPro Hemi Implant.
  • Data collection included patient demographics, surgical technique (with or without long flexor transfer), and radiographic measurements (dorsiflexion, plantarflexion, first intermetatarsal angle, first-ray elevatus).
  • Postoperative outcomes assessed included gait, hallux purchase, cosmesis, shoe wear, pain relief, patient satisfaction, and the American College of Foot and Ankle Surgeons Universal Evaluation score.

Main Results:

  • Significant improvements were observed in first MTP joint dorsiflexion (36.13° to 56.92°) and plantarflexion (2.71° to 9.05°).
  • Radiographic improvements included a decrease in the first intermetatarsal angle (8.65° to 8.41°) and prevalence of first-ray elevatus (65.82% to 55.70%).
  • High rates of patient satisfaction (86.08%), normal hallux purchase (93.67%), and ability to wear conventional shoes (53.16%) were reported, with a mean postoperative American College of Foot and Ankle Surgeons Universal Evaluation score of 94.00.

Conclusions:

  • First MTP joint hemiarthroplasty with the BioPro Hemi Implant demonstrates favorable outcomes in terms of joint mobility and radiographic alignment.
  • The procedure leads to significant improvements in patient-reported satisfaction and functional ability, including pain relief and shoe wear.
  • The BioPro Hemi Implant is a useful option for managing first MTP joint degeneration, with a low overall complication rate of 10.13%.