Related Experiment Video
Updated: Jun 13, 2026

Ion Exchange Chromatography (IEX) Coupled to Multi-angle Light Scattering (MALS) for Protein Separation and Characterization
Published on: April 5, 2019
Lysine-based zwitterionic molecular micelle for simultaneous separation of acidic and basic proteins using open
Leonard Moore1, Zorabel M LeJeune, Candace A Luces
1Department of Chemistry, Louisiana State University, Baton Rouge, Louisiana 70803, USA.
Abstract:
In this work, a zwitterionic molecular micelle, poly-epsilon-sodium-undecanoyl lysinate (poly-epsilon-SUK), was synthesized and employed as a coating in open tubular capillary electrochromatography (OT-CEC) for protein separation. The zwitterionic poly-epsilon-SUK containing both carboxylic acid and amine groups can be either protonated or deprotonated depending on the pH of the background electrolyte; therefore, either an overall positively or negatively charged coating can be achieved. This zwitterionic coating allows protein separations in either normal or reverse polarity mode depending on the pH of the background electrolyte. The protein mixtures contained four basic proteins (lysozyme, cytochrome c, alpha-chymotrypsinogen A, and ribonuclease A) and six acidic proteins (myoglobin, deoxyribonuclease I, beta-lactoglobulin A, beta-lactoglobulin B, alpha-lactalbumin, and albumin). Protein separations were optimized specifically for acidic (reverse mode) and basic (normal mode) pH values. Varying the polymer thickness by changing the polymer and salt concentration had a great influence on protein resolution, while nearly all peaks were also baseline resolved in both modes using the optimized poly-epsilon-SUK coating concentration of 0.4% (w/v). Proteins in human sera were separated under optimized acidic and basic conditions in order to demonstrate the general utility of this coating. Nanoscale characterizations of the poly-epsilon-SUK micellar coatings on silicon surfaces were accomplished using atomic force microscopy (AFM) to gain insight into the morphology and thickness of the zwitterionic coating. The thickness of the polymer coating ranged from 0.9 to 2.4 nm based on local measurements using nanoshaving, an AFM-based method of nanolithography.
Related Concept Videos
Capillary Electrophoresis: Applications
Capillary zone electrophoresis (CZE) separates ionic components based on their electrophoretic mobility. It has been used to separate proteins, amino acids,...
Ion-Exchange Chromatography
Two-dimensional Gel Electrophoresis
The first dimension separation uses the isoelectric focusing or IEF technique performed on immobilized pH gradient (IPG) strips that separate proteins according to their isoelectric points.
Biological samples, such as cells...
Detergent Purification of Membrane Proteins
Ion Exchange
SDS-PAGE
A variation of gel electrophoresis, termed polyacrylamide gel electrophoresis (PAGE), is commonly used for separating proteins according to their molecular size by passing them through a polyacrylamide gel. Because of the varying charges associated with amino acid side chains, PAGE can be used to separate intact proteins...

