Related Experiment Video
Updated: Jun 13, 2026

Experimental Methods of Dust Charging and Mobilization on Surfaces with Exposure to Ultraviolet Radiation or Plasmas
Published on: April 3, 2018
Note: Design and tests of a 13 kA-6.5 kV thyristor switch for a pulsed inductive vacuum ultraviolet source
1Plasmaphysics Group, Institute of Applied Physics, Goethe University, Frankfurt am Main 60438, Germany.
Abstract:
In this paper, the design, construction, and test procedure of a closing switch prototype based on thyristors is described. In particular, details are given about the design criteria and about the triggering board architecture, which is a high side biased, self supplied unit using the electrical energy derived from a local snubber network for the gate drive. The structure guarantees a hard firing gate pulse for the required high dI/dt application. Further, the results of the prototype tests are presented and discussed. The stack assembly has a holding voltage of 6.5 kV and is used for switching a series resonant circuit with a ringing frequency of 12 kHz for a pulsed inductive vacuum ultraviolet source. Maximum current amplitudes of 13 kA and pulse energies of more than 600 J were switched during the test procedure.