Related Experiment Video
Updated: Jun 13, 2026

A Simple, Robust, and High Throughput Single Molecule Flow Stretching Assay Implementation for Studying Transport of Molecules Along DNA
Published on: October 1, 2017
Diffusion as major source of band broadening in field-amplified sample stacking under negligible electroosmotic flow
1Central Division of Analytical Chemistry, Research Centre Jülich, D-52425 Jülich, Germany.
Abstract:
Theory of field-amplified sample stacking (FASS) also called field-enhanced sample stacking is reevaluated considering the early work of Chien, Burgi and Helmer. The classical theory presented by Chien, Helmer and Burgi predicts the existence of maxima, which are ascribed to the counteracting principles of zone focusing and hydrodynamic dispersion. In contrast to their work, we here focus on cationic analytes separated in an acidic background electrolyte providing a very low electroosmotic flow velocity. Therefore, peak broadening due to differences in the local electroosmotic flow velocities in different compartments of the capillary can be regarded to be negligible. Consequently, peak broadening resulting from hydrodynamic dispersion will not be the dominant limitation of the accessible enrichment efficiency. In our experimental studies we, however, obtain an optimum value for the field enhancement factor (maximum of the enrichment efficiency, when varying the electric conductivity of the sample and the size of the sample injection plug) corresponding to a 10-fold dilution of the BGE in the sample solution. Comparing these experimental data with data modeled according to the revised theory, we show that this limitation of the loadability is caused by the unavoidable decrease of the analyte migration velocity in the BGE compartment of the capillary when injecting of a sample plug of lower electric conductivity (decrease in the local electric field strength). The additional diffusional band broadening limits the obtainable enrichment efficiency.
Related Concept Videos
Diffusion on Chromatography Columns
Longitudinal diffusion occurs when the solute molecules in the mobile phase diffuse from the more concentrated center of the chromatographic band to the more dilute regions on either side, both towards and against the flow direction. This...
Capillary Electrophoresis: Instrumentation
Column Efficiency: Rate Theory
During elution, a solute molecule experiences numerous transitions between stationary and mobile phases, exhibiting irregular residence times in...
Bandpass Sampling
A bandpass signal has a spectrum with a lower frequency limit, denoted as ω1, and an upper frequency limit, denoted as ω2. The spectrum...
Electrophoresis: Overview
There...
Protein Diffusion in the Membrane