Breakdown of linear response induced by velocity-dependent stochastic resetting

Yuto Takeishi1, Takuma Akimoto1

  • 1Tokyo University of Science, Department of Physics and Astronomy, Noda, Chiba 278-8510, Japan.

Physical Review. E
|October 17, 2026
PubMed

Related Concept Videos

Transient and Steady-state Response01:24

Transient and Steady-state Response

In control systems, test signals are essential for evaluating performance under various conditions. The ramp function is effective for systems undergoing gradual changes, while the step function is suitable for assessing systems facing sudden disturbances. For systems subjected to shock inputs, the impulse function is the most appropriate test signal.
These test signals are integral in designing control systems to exhibit two key performance aspects: transient response and steady-state response.
Linear Approximation in Frequency Domain01:26

Linear Approximation in Frequency Domain

Linear systems are characterized by two main properties: superposition and homogeneity. Superposition allows the response to multiple inputs to be the sum of the responses to each individual input. Homogeneity ensures that scaling an input by a scalar results in the response being scaled by the same scalar.
In contrast, nonlinear systems do not inherently possess these properties. However, for small deviations around an operating point, a nonlinear system can often be approximated as linear.
Linear Approximation in Time Domain01:21

Linear Approximation in Time Domain

Nonlinear systems often require sophisticated approaches for accurate modeling and analysis, with state-space representation being particularly effective. This method is especially useful for systems where variables and parameters vary with time or operating conditions, such as in a simple pendulum or a translational mechanical system with nonlinear springs.
For a simple pendulum with a mass evenly distributed along its length and the center of mass located at half the pendulum's length, the...
Types of Responses of Series RLC Circuits01:11

Types of Responses of Series RLC Circuits

A second-order differential equation characterizes a source-free series RLC circuit, marking its distinct mathematical representation. The complete solution of this equation is a blend of two unique solutions, each linked to the circuit's roots expressed in terms of the damping factor and resonant frequency.
Second Order systems II01:18

Second Order systems II

In an underdamped second-order system, where the damping ratio ζ is between 0 and 1, a unit-step input results in a transfer function that, when transformed using the inverse Laplace method, reveals the output response. The output exhibits a damped sinusoidal oscillation, and the difference between the input and output is termed the error signal. This error signal also demonstrates damped oscillatory behavior. Eventually, as the system reaches a steady state, the error diminishes to zero.
If  ζ...
Fast Reactions01:27

Fast Reactions

Fast reactions occurring in times shorter than the time needed to mix reactants pose a unique challenge for investigation. In a liquid-phase continuous-flow system, reactants A and B are swiftly pushed into the mixing chamber, where mixing occurs within 1 ms. The reaction mixture then flows through an observation tube, and one measures light absorption to determine species concentrations at various points of the tube. This method is most appropriate when relatively large volumes of reactants...