Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Pre-Procedural Guidelines for Assessing Blood Pressure01:10

Pre-Procedural Guidelines for Assessing Blood Pressure

Accurate blood pressure assessment is crucial for diagnosing and managing various health conditions. To ensure the reliability of these measurements, healthcare professionals must adhere to standardized pre-procedural guidelines. These guidelines enhance patient safety and improve the overall quality of healthcare. The following steps are essential for obtaining accurate and consistent blood pressure readings, from using the appropriate tools to ensuring effective communication with the patient.
Assessment of blood pressure in brachial artery(one-step method)01:15

Assessment of blood pressure in brachial artery(one-step method)

This procedural guide systematically measures blood pressure using an oscillometric digital sphygmomanometer, emphasizing accuracy, patient safety, and comfort.
Prepare for the Procedure:
Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Assessment of blood pressure in brachial artery(two-step method)01:23

Assessment of blood pressure in brachial artery(two-step method)

Measuring blood pressure is a fundamental skill in healthcare that aids in diagnosing and monitoring hypertension and other cardiovascular conditions. An aneroid sphygmomanometer, commonly used in clinical settings, offers a manual and precise method for blood pressure measurement. The technique for using this instrument involves specific steps that must be carefully executed to ensure accuracy. The following detailed description outlines a two-step technique for assessing blood pressure using...
Sites for measuring blood pressure01:21

Sites for measuring blood pressure

Blood pressure measurement is a fundamental clinical procedure, providing crucial data for assessing cardiovascular health. Among the various sites for this measurement, the brachial and popliteal arteries are predominantly utilized due to their accessibility and the reliability of their readings. This lesson delves into the anatomical significance, methodology, and considerations of measuring blood pressure at these locations.
The Brachial Artery: Primary Site for Blood Pressure Measurement
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Relationship Between Nonuniform Isochrone-Area in Late Activation Mapping and Arrhythmogenic Substrates Related to Atrial Fibrillation.

Journal of cardiovascular electrophysiology·2026
Same author

Temporal Trends in Antineoplastic Agent-associated Interstitial Lung Disease Involving Immune Checkpoint Inhibitors in the JADER Database.

In vivo (Athens, Greece)·2026
Same author

Diagnostic performance of commercial AI systems versus participating radiologists for pulmonary nodule detection in routine clinical practice.

Japanese journal of radiology·2026
Same author

Diet-induced obesity exacerbates and prolongs postoperative pain via peripheral DRG transcriptional changes in rats.

Journal of dental anesthesia and pain medicine·2026
Same author

Association Between Nasal Packing and 72-Hour Emergency Department Revisits in Adult Epistaxis: A Single-Center Retrospective Cohort Study.

Journal of the American College of Emergency Physicians open·2026
Same author

Optimizing Single-Lead Electrocardiogram Orientation Improves Detection of Left Ventricular Dysfunction.

Circulation journal : official journal of the Japanese Circulation Society·2026

Related Experiment Video

Updated: Jun 13, 2026

Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
04:44

Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function

Published on: March 22, 2024

A new reusable skin-protective sphygmomanometer cuff.

Eri Gi1, Hiroaki Watanabe, Shigekazu Sugino

  • 1Department of Anesthesiology, Sapporo Medical University, Chuo-ku, Hokkaido, Japan. eri@sapmed.ac.jp

Journal of Clinical Monitoring and Computing
|May 12, 2010
PubMed
Summary

A new reusable sphygmomanometer cuff with a protective sheet reduces skin damage and pain during blood pressure measurement. This innovation ensures accurate readings while enhancing patient comfort in clinical settings.

More Related Videos

A Modified Cuff Technique for Mouse Cervical Heterotopic Heart Transplantation Model
06:45

A Modified Cuff Technique for Mouse Cervical Heterotopic Heart Transplantation Model

Published on: February 7, 2022

Optimization of the Cuff Technique for Murine Heart Transplantation
14:01

Optimization of the Cuff Technique for Murine Heart Transplantation

Published on: June 26, 2020

Related Experiment Videos

Last Updated: Jun 13, 2026

Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function
04:44

Near-Infrared Spectroscopy During Reactive Hyperemia for the Assessment of Lower Limb Vascular Function

Published on: March 22, 2024

A Modified Cuff Technique for Mouse Cervical Heterotopic Heart Transplantation Model
06:45

A Modified Cuff Technique for Mouse Cervical Heterotopic Heart Transplantation Model

Published on: February 7, 2022

Optimization of the Cuff Technique for Murine Heart Transplantation
14:01

Optimization of the Cuff Technique for Murine Heart Transplantation

Published on: June 26, 2020

Area of Science:

  • Biomedical Engineering
  • Clinical Measurement

Background:

  • Repeated non-invasive blood pressure (NIBP) measurements using traditional sphygmomanometer cuffs can cause adverse skin reactions like redness and subcutaneous bleeding.
  • Existing cuffs may lead to patient discomfort and potential skin damage during frequent use in clinical environments.

Purpose of the Study:

  • To develop and evaluate a novel reusable sphygmomanometer cuff designed with an integrated skin-protective sheet.
  • To assess the efficacy of the new cuff in mitigating skin damage and ensuring accurate blood pressure measurements.

Main Methods:

  • The study involved evaluating skin damage and the accuracy of blood pressure measurements with the new protective cuffs.
  • Computed tomography (CT) scans were used to assess upper arm deformation during cuff inflation.
  • Pulse wave amplitude was analyzed using an NIBP simulator and a custom-developed system.

Main Results:

  • The novel skin-protective cuff significantly reduced instances of subcutaneous bleeding and reported pain associated with cuff inflation.
  • Accurate blood pressure measurements were maintained with the use of the enhanced cuff.
  • CT scans indicated no significant upper arm deformity during cuff inflation with the new design.

Conclusions:

  • A new, reusable skin-protective sphygmomanometer cuff has been successfully developed.
  • This innovative cuff design offers a solution to minimize skin trauma and discomfort during NIBP monitoring.