Enhanced external counterpulsation: mechanisms of action and clinical applications

Vasiliki Kitsou1, Theodoros Xanthos, Robin Roberts

  • 1Department of Experimental Surgery and Surgical Research, University of Athens, Greece.

Acta Cardiologica
|May 13, 2010
PubMed

Insights

Enhanced external counterpulsation (EECP) is a safe and effective non-invasive treatment for coronary artery disease and heart failure. This therapy improves patient quality of life and shows promise for other cardiac conditions.

Area of Science:

  • Cardiology
  • Medical Devices
  • Non-invasive Therapies

Background:

  • Symptomatic coronary artery disease (CAD) and heart failure (HF) are prevalent conditions.
  • Optimal medical and revascularisation treatments do not fully manage a significant patient subset.
  • Non-pharmacological, non-invasive options are sought for refractory cases.

Purpose of the Study:

  • To evaluate the efficacy and safety of enhanced external counterpulsation (EECP) as a treatment modality.
  • To explore EECP's role in managing ischaemic heart disease, heart failure, and cardiac syndrome X.
  • To assess EECP's potential beyond traditional heart disease indications.

Main Methods:

  • EECP involves sequential inflation/deflation of pneumatic leg cuffs synchronized with the cardiac cycle.
  • Administered in an outpatient setting.
  • Clinical trials have assessed EECP in patients with ischaemic heart disease and heart failure.

Main Results:

  • Numerous trials demonstrate EECP is safe and effective for ischaemic heart disease, improving quality of life.
  • EECP shows benefit as adjunctive therapy in heart failure of any aetiology.
  • Cardiac syndrome X has been effectively treated with EECP.

Conclusions:

  • EECP is a highly effective non-invasive treatment for symptomatic CAD and HF.
  • EECP improves quality of life in patients with ischaemic heart disease.
  • Further sham-controlled trials are needed to solidify EECP's place in medical practice.

Related Concept Videos

Equipments Used To Measure Blood Pressure01:30

Equipments Used To Measure Blood Pressure

Direct Method
This invasive approach involves cannulating a peripheral artery. During each cardiac contraction, pressure generates mechanical motion within the catheter, transmitted through rigid, fluid-filled tubing to a transducer. This transducer converts mechanical motion into electrical signals displayed as waveforms on a monitor. An automatic flushing system prevents blood backflow. Due to the potential risk of unexpected arterial blood loss, this method is primarily used in intensive...
Measurement of Blood Pressure01:17

Measurement of Blood Pressure

Assessing blood pressure is a standard procedure executed in virtually all medical environments. The method utilized today was established over a hundred years ago by an innovative Russian doctor, Dr. Nikolai Korotkoff. The soft ticking noise, known as Korotkoff sounds, heard while taking blood pressure readings results from turbulent blood flow within the vessels. The apparatus required for this procedure includes a sphygmomanometer, a blood pressure cuff attached to a gauge, and a stethoscope.
Pulse01:16

Pulse

When the heart pumps blood out, arterial elastic fibers play a crucial role in sustaining a high-pressure gradient. They expand to accommodate the received blood and then recoil - a process known as the pulse that can be either manually palpated or electronically quantified. Despite a reduction in its effect with increased distance from the heart, elements of the pulse's systolic and diastolic components persist, observable even at the arteriole level.
The pulse serves as a clinical indicator...
Treatment for Pulmonary Arterial Hypertension: Prostacyclin Receptor Agonists01:23

Treatment for Pulmonary Arterial Hypertension: Prostacyclin Receptor Agonists

Prostacyclin receptor agonists are a class of therapeutic agents integral to managing pulmonary arterial hypertension (PAH). These drugs operate by mimicking the action of prostaglandin I2, or PGI2, a naturally occurring compound in the body.
These agonists bind to the IPR receptor situated on the plasma membrane of the pulmonary artery smooth muscle cells. This binding triggers a cascade of reactions known as the GS-AC-cAMP-PKA pathway. This pathway results in the relaxation of smooth muscle...
Assessing Blood pressure using a doppler ultrasound01:19

Assessing Blood pressure using a doppler ultrasound

To obtain accurate blood pressure measurements in clinical settings, especially when traditional methods are insufficient, healthcare professionals utilize the Doppler ultrasound technique. This method uses high-frequency sound waves to detect blood flow within the arteries, which is crucial for patients with conditions that complicate circulatory system assessment.
Pre-Procedural Guidelines for Doppler Ultrasound Blood Pressure Assessment:
Preparation of Equipment:
Heart Failure VI: Adjunct Therapies01:22

Heart Failure VI: Adjunct Therapies

Additional therapies for treating patients with heart failure (HF) may include procedural interventions, supplemental oxygen, the management of sleep disorders, and nutritional therapy.Procedural InterventionsImplantable Cardioverter-Defibrillator: For patients at risk of life-threatening arrhythmias due to severe left ventricular dysfunction, an Implantable Cardioverter-Defibrillator (ICD) can detect and terminate these arrhythmias, preventing sudden cardiac death and improving survival rates.