Related Experiment Video
Updated: Jun 13, 2026

Adjustable Stiffness, External Fixator for the Rat Femur Osteotomy and Segmental Bone Defect Models
Published on: October 9, 2014
In vitro comparison of a novel external fixator and traditional full-limb transfixation pin cast in horses
James N Nutt1, Louise L Southwood, Yvonne A Elce
1Richard S. Reynolds, Jr. Comparative Orthopedic Research Laboratory, Department of Clinical Studies, New Bolton Center, School of Veterinary Medicine, University of Pennsylvania, Kennett Square, PA 19348, USA.
Objective:
To compare the mechanical properties and failure modes of a standardized short oblique distal radial metaphyseal osteotomy stabilized using either a transfixation pin cast (TPC), a modular-sidebar external skeletal fixator (ESF), or a solid-sidebar ESF (modular- or solid-ESF, respectively) using static or cyclic axial loading to failure.
Study Design:
In vitro study.
Animals:
Equine cadaver forelimbs.
Methods:
A 30 degrees oblique distal radial osteotomy was created and stabilized using 1 of the 3 fixation methods: (1) TPC, (2) modular-ESF, or (3) solid-ESF. Limbs were tested using static (TPC, modular-ESF, and solid-ESF) or cyclic (TPC and solid-ESF) axial loading to failure. The stiffness, yield load, yield displacement, failure load, and failure displacement for static loading and the cycles to failure for cyclic loading at 75% failure load were obtained. Data were analyzed using a Kruskal-Wallis test. Level of significance was P<.05.
Results:
The solid-ESF had a greater stiffness, higher yield and failure load and a lower yield and failure displacement than the TPC (P=.01) and the modular-ESF (P=.02). TPC had a higher yield load, failure load, and yield displacement than the modular-ESF (P=.01). Mean cycles to failure for TPC was 2996+/-657 at a load of 16,000 N and for solid-ESF 6560+/-90 cycles at a load of 25,000 N.
Conclusions:
The solid-ESF was stiffer and stronger than the TPC and modular-ESF and failed at a greater number of cycles in axial loading compared with the TPC.
Clinical Relevance:
This study is an initial step in evaluating the solid-ESF. Further testing needs to be performed, but this fixation may offer a viable alternative to the traditional TPC for stabilization of long bone fractures in adult horses.
More Related Videos
08:20A Reliable and Reproducible Critical-Sized Segmental Femoral Defect Model in Rats Stabilized with a Custom External Fixator
Published on: March 24, 2019
07:41An Intramedullary Locking Nail for Standardized Fixation of Femur Osteotomies to Analyze Normal and Defective Bone Healing in Mice
Published on: November 13, 2016