Related Experiment Video
Updated: Jun 13, 2026

08:00
DNA Nanotubes as a Versatile Tool to Study Semiflexible Polymers
Published on: October 25, 2017
Tunable alignment for all polymer gel/solvent combinations for the measurement of anisotropic NMR parameters
Grit Kummerlöwe1, Elizabeth F McCord, Steve F Cheatham
1Department Chemie, Technische Universität München, Lichtenbergstr. 4, 85747 Garching, Germany.
Chemistry (Weinheim an Der Bergstrasse, Germany)
|May 15, 2010
Abstract
No abstract available in PubMed .
More Related Videos
Related Concept Videos
¹H NMR of Conformationally Flexible Molecules: Temporal Resolution
At room temperature, the chair conformer of cyclohexane undergoes rapid ring flipping between two equivalent chair conformers at a rate of approximately 105 times per second. These two chair conformers are in equilibrium. The rapid ring flipping results in the interconversion of the axial proton to an equatorial proton and an equatorial to the axial proton. Such interconversions are too rapid and cannot be detected on the NMR timescale. Hence, the NMR spectrometer cannot distinguish between the...
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
The axial and equatorial protons in cyclohexane can be distinguished by performing a variable-temperature NMR experiment. In this process, except for one proton, the remaining eleven protons are replaced by deuterium. The deuterium substitution avoids the possible peak splitting caused by the spin-spin coupling between the adjacent protons. The remaining proton flips between the axial and equatorial positions.
¹H NMR: Interpreting Distorted and Overlapping Signals
Spin systems where the difference in chemical shifts of the coupled nuclei is greater than ten times J are called first-order spin systems. These nuclei are weakly coupled, and their chemical shifts and coupling constant can generally be estimated from the well-separated signals in the spectrum.
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
As Δν decreases and the signals move closer, the doublets appear increasingly distorted. The intensities of the inner lines increase at the cost of those of the outer lines as the signals are slanted or...
Chemical Shift: Internal References and Solvent Effects
In an NMR sample, precise measurement of the absolute absorption frequencies of nuclei is difficult. A standard internal reference compound is added, and the frequency difference between the reference signal and sample signals is measured.
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
The internal reference compound generally used in NMR spectroscopy is tetramethylsilane (TMS). TMS is preferred because it is chemically inert, soluble in NMR solvents, and easily removable. Also, the highly shielded methyl protons in TMS yield an intense...
¹H NMR Chemical Shift Equivalence: Enantiotopic and Diastereotopic Protons
Replacing each alpha-hydrogen in chloroethane by bromine (or a different functional group) yields a pair of enantiomers. Such protons are called prochiral or enantiotopic and are related by a mirror plane. Enantiotopic protons are chemically equivalent in an achiral environment. Because most proton NMR spectra are recorded using achiral solvents, enantiotopic hydrogens yield a single signal.
In chiral compounds such as 2-butanol, replacing the methylene hydrogens at C3 produces a pair of...
In chiral compounds such as 2-butanol, replacing the methylene hydrogens at C3 produces a pair of...
NMR Spectrometers: Resolution and Error Correction
When magnetic nuclei in a sample achieve resonance and undergo relaxation, the signal detected in NMR is an approximately exponential free induction decay. Fourier transform of an exponential decay yields a Lorentzian peak in the frequency domain. Lorentzian peaks in an NMR spectrum are defined by their amplitude, full width at half maximum, and position, where the peak width is governed by the spin-spin relaxation time alone. In real experiments, however, the applied magnetic field is rendered...

