A case of difficulty predicting neurological deficit during thoracoabdominal aortic surgery
Jonathan D Leff1, K S Sudheera, Linda Shore-Lesserson
1Department of Anesthesiology, Montefiore Medical Center, Bronx, NY 10467, USA. jleff@montefiore.org
Abstract:
Perioperative spinal cord injury associated with thoracoabdominal aorta (TAAA) surgery is a devastating complication. With variable results, the intraoperative use of neurophysiologic monitoring has been employed for the diagnosis and prevention of spinal cord ischemia. We present a case report of a patient undergoing TAAA surgery with the use of evoked potential monitoring. Intraoperatively, both sensory and motor evoked potentials were utilized and consequently the patient experienced changes in monitoring consistent with a new neurologic deficit. However, postoperatively these changes in evoked potentials never manifested in neurologic injury. We examine the utility of neurophysiologic monitoring as it pertains to TAAA surgery.