Related Experiment Video
Updated: Jun 13, 2026

The Transition to an Anterior-Based Muscle Sparing Approach Improves Early Postoperative Function but is Associated with a Learning Curve
Published on: September 7, 2022
Gait analysis after total hip replacement with hip resurfacing implant or Mallory-head Exeter prosthesis: a
Mette K Petersen1, Niels T Andersen, Poul Mogensen
1Department of Orthopaedics, Aarhus Sygehus, Aarhus University Hospital, Aarhus C, Denmark. mekp@mail.dk
Abstract:
A key to the analysis of function after total hip replacement (THR) is the ability to identify gait adaptations specific to design features and surgical procedures. In a randomised controlled design, we evaluated the mechanics of gait after THR with a hip resurfacing system or conventional prosthesis. We also investigated whether gait adaptations returned to normal postoperatively. Similar improvements in mechanics of gait were found, except for peak abductor moments, which improved more in the conventional group. Gait speed increased significantly, but with no differences between groups. The increase in walking speed was reflected as significant improvement within groups in most kinematic and kinetic variables. Significant differences between the operated and non-operated hip were seen in all patients, but with no difference between groups. Mean curves of joint angle profiles and moments in all anatomical planes during a gait cycle revealed that gait impairment persisted with no differences between the conventional prosthesis and the resurfacing system.