Related Experiment Video
Updated: Jun 12, 2026

Elucidating the Metabolism of 2,4-Dibromophenol in Plants
Published on: February 10, 2023
Brominated flame retardants in offices in Michigan, USA
Stuart Batterman1, Christopher Godwin, Sergei Chernyak
1Environmental Health Sciences, University of Michigan, Ann Arbor, MI 48109-2029, USA. Stuartb@umich.edu
Abstract:
Brominated flame retardants (BFRs) are now ubiquitous contaminants with large reservoirs and high concentrations in buildings. Most of the information documenting BFR levels has been obtained in residences, and other environments that can lead to exposure have received relatively little attention, including offices that contain numerous BFR sources and where individuals spend considerable time. The aim of this study is to characterize BFR concentrations, potential emission sources, and migration pathways in office environments. We measure BFR levels in floor dust, indoor air, ventilation filter dust, and carpets in ten commercial and institutional buildings in Michigan, U.S.A. The median concentration of total BDEs in settled dust was 8754 ng g(-1), at the upper range of levels previously reported. Especially elevated levels were found in offices in buildings that contained known or likely BFR sources, e.g., computer servers. A trends analysis in a newly constructed building showed remarkable increases in concentrations of BFRs in settled dust and indoor air, and apparent steady-state levels were reached 5 to 8 months after building completion, a particularly striking finding given that the building was constructed and furnished several years after the voluntary phase-out of the penta- and octa-mixtures. Airborne particulate matter collected in a building's HVAC system filters contained PBDEs, including BDE-209, at levels exceeding the concentration of floor dust. In conjunction with estimates of building air flow rates, filter efficiency and other parameters, mass balance calculations for this building were used to estimate the emission rates and reservoirs of PBDEs. The widespread distribution of BFRs found in offices in both new and old buildings suggests the significance of workplace exposures, the need for controls to minimize human exposure, intra-building migration, and environmental releases of these chemicals, and the need for monitoring in new buildings to confirm the effectiveness of the PBDE phase-out.
More Related Videos
14:06Rapid Testing of Resistance of Timber to Biodegradation by Marine Wood-Boring Crustaceans
Published on: January 29, 2022
09:04Identifying Per- and Polyfluorinated Chemical Species with a Combined Targeted and Non-Targeted-Screening High-Resolution Mass Spectrometry Workflow
Published on: April 18, 2019
Related Concept Videos
Electrophilic Aromatic Substitution: Fluorination and Iodination of Benzene
Electrophilic Aromatic Substitution: Chlorination and Bromination of Benzene
Toxic Reactions: Overview
Toxicity falls into two primary categories: local and systemic.
Local toxicity appears at the exposure site, such as protein denaturation caused by caustic substances.
In contrast, systemic toxicity requires the toxic agent's absorption and distribution,...
Types of Toxins
Air pollutants, primarily gases, pose significant threats to respiratory health, leading to conditions like hypoxia, lung cancer, and in extreme cases, death.
Environmental pollutants like...
Halogenation of Alkenes
Consider the bromination of cyclopentene. Molecular bromine is polarized in the proximity of the π electrons of cyclopentene. An electrophilic bromine atom adds across the double bond, forming a cyclic bromonium ion intermediate.
Radical Substitution: Allylic Bromination