Jove
Visualize
Contact Us
JoVE
x logofacebook logolinkedin logoyoutube logo
ABOUT JoVE
OverviewLeadershipBlogJoVE Help Center
AUTHORS
Publishing ProcessEditorial BoardScope & PoliciesPeer ReviewFAQSubmit
LIBRARIANS
TestimonialsSubscriptionsAccessResourcesLibrary Advisory BoardFAQ
RESEARCH
JoVE JournalMethods CollectionsJoVE Encyclopedia of ExperimentsArchive
EDUCATION
JoVE CoreJoVE BusinessJoVE Science EducationJoVE Lab ManualFaculty Resource CenterFaculty Site
Terms & Conditions of Use
Privacy Policy
Policies

Related Concept Videos

Distance Corrections01:15

Distance Corrections

To achieve precise distance measurements, especially in surveying and construction, certain corrections must be applied to account for potential sources of error like the standardization errors, temperature variations, and slope adjustments.Standardization error emerges when measurement equipment undergoes changes, such as wear, repairs, or weather impacts. To address this, surveyors compare the equipment’s readings to a standard. This process identifies any deviation that might lead to...
Common Leveling Mistakes and Errors01:17

Common Leveling Mistakes and Errors

A survey team is tasked with determining the elevation difference between points Point A and Point B, separated by uneven terrain. They use a leveling instrument and a leveling rod.Common MistakesMisreading the Rod: During a backsight reading at Point A, the instrumentman observes the rod partially obscured by tall grass. Instead of reading 1.135 m, they mistakenly record 1.735 m due to the misalignment of the crosshair with the wrong graduation. This error adds 0.600 m to all subsequent...
Focusing of Light in the Eye01:16

Focusing of Light in the Eye

Light rays enter the eye through the cornea, a transparent dome-shaped tissue that is the eye's outermost layer. The cornea bends or refracts, light rays traveling to the pupil. The shape of the cornea determines how much of the light is bent and whether the image will be focused correctly on the retina at the back of the eye. Once the light has passed through both refraction layers, it converges into a single focal point onto a small area. This is where photoreceptors start transforming...
Adjusting a Traverse01:12

Adjusting a Traverse

In the site survey of a four-sided traverse, internal angles are essential to ensure geometric accuracy. The survey revealed that the sum of the measured internal angles was 359 degrees and 48 minutes, which is 12 minutes less than the expected 360 degrees. This discrepancy signals an error likely arising from measurement inaccuracies during the fieldwork.To rectify this error, the adjustment process involved distributing the 12-minute shortfall equally across the four internal angles. By...
Phase Contrast and Differential Interference Contrast Microscopy01:26

Phase Contrast and Differential Interference Contrast Microscopy

Phase-Contrast Microscopes
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...

You might also read

Related Articles

Articles linked to this work by shared authors, journal, and citation graph.

Sort by
Same author

Rationale and Emerging Evidence on the Potential Role of HoLEP-Mediated Relief of Bladder Outlet Obstruction in NMIBC Outcomes Through Optimal Management of Chronic Urinary Retention.

Cancers·2025
Same author

Impact of On-Demand Selective Suturing on Renal Function Preservation During Clampless Robotic-Assisted Partial Nephrectomy: Insights from a Large Multicentric Italian Cohort.

Journal of clinical medicine·2025
Same author

The Role of Holmium Laser Enucleation of the Prostate in Reducing the Risk of Bladder Cancer Recurrence and Progression.

Journal of endourology·2025
Same author

Direct interaction between TDP-43 and Tau promotes their co-condensation, while suppressing Tau fibril formation and seeding.

The EMBO journal·2025
Same author

Local Recurrence After Nephron Surgery: What to Do? An Italian Multicentric Registry.

Cancers·2025
Same author

Transition to robotic surgery in urologic oncology: a comparative analysis between pre-robotic and robotic eras in a high-volume tertiary center.

Journal of robotic surgery·2025

Related Experiment Video

Updated: Jun 12, 2026

Bringing the Visible Universe into Focus with Robo-AO
10:35

Bringing the Visible Universe into Focus with Robo-AO

Published on: February 12, 2013

Schmidt camera correctors for large telescopes.

Andrea Romoli1, Alessandro Zuccaro Marchi, Lisa Gambicorti

  • 1Consiglio Nazionale delle Ricerche, Istituto Nazionale di Ottica,Largo Enrico Fermi 6, 50125 Firenze, Italy.

Applied Optics
|May 22, 2010
PubMed
Summary
This summary is machine-generated.

A new recursive method offers improved spherical aberration correction for large Schmidt cameras, surpassing traditional polynomial expansion designs. This technique enhances optical performance and is being integrated into new software for broader application.

More Related Videos

A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors
11:15

A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors

Published on: May 30, 2016

Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy
08:49

Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy

Published on: December 1, 2023

Related Experiment Videos

Last Updated: Jun 12, 2026

Bringing the Visible Universe into Focus with Robo-AO
10:35

Bringing the Visible Universe into Focus with Robo-AO

Published on: February 12, 2013

A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors
11:15

A Guide to Structured Illumination TIRF Microscopy at High Speed with Multiple Colors

Published on: May 30, 2016

Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy
08:49

Multimodal Nonlinear Hyperspectral Chemical Imaging Using Line-Scanning Vibrational Sum-Frequency Generation Microscopy

Published on: December 1, 2023

Area of Science:

  • Optical Engineering
  • Astronomy Instrumentation

Background:

  • Large Schmidt cameras are crucial for astronomical surveys.
  • Polynomial expansion methods for corrector design can result in imperfect spherical aberration correction.

Purpose of the Study:

  • To present an alternative, more accurate method for designing Schmidt corrector plates.
  • To address the limitations of polynomial expansion in aberration correction.

Main Methods:

  • A novel recursive method is introduced for determining the corrector's shape.
  • Calculation of incidence points and surface normal vectors for any ray is detailed.

Main Results:

  • The recursive method provides a more precise solution for spherical aberration correction.
  • The method allows for detailed ray tracing and surface normal analysis.

Conclusions:

  • The proposed recursive method offers a superior alternative for designing Schmidt camera correctors.
  • This approach is expected to improve the optical quality of large astronomical instruments.