Related Experiment Video
Updated: Jun 12, 2026

A Method for Studying the Temperature Dependence of Dynamic Fracture and Fragmentation
Published on: June 28, 2015
Measurement of 9 mm cartridge case external temperatures and its forensic application
B Gashi1, M R Edwards, P A Sermon
1Department of Applied Science, Security and Resilience, Cranfield University, Shrivenham, Swindon SN6 8LA, UK.
Abstract:
The external temperature of the cartridge cases of 9 mm parabellum ammunition during the firing sequence was measured by a series of methods. Using a thermal imaging camera was the most successful method and showed that aluminium alloy cases reached higher temperatures than did brass cases. Peak temperatures for brass cases were 336 K at the case mouth after 1.2 ms and 331 K at the case base after 2 ms. Corresponding temperatures for aluminium alloy cases were 363 K at the mouth after 0.8 ms and 372 K at the base after 1.2 ms. These times at temperature would not be sufficient to destroy any DNA residues left on the case. Measurement of the DNA of fired cartridges showed that DNA deposited on the cartridge case before firing was not affected by the temperatures reached during the firing sequence. Estimates of temperatures to be found in pure aluminium and mild steel cases were made, these indicating that pure aluminium would give higher temperatures than aluminium alloy and steel a lower temperature than for brass.
Related Concept Videos
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Physical Methods for Controlling Microbial Growth: Temperature