Temperature monitored on the cuff surface of an endotracheal tube reflects body temperature
Related Experiment Video
Updated: Jun 12, 2026

Using an Ingestible Telemetric Temperature Pill to Assess Gastrointestinal Temperature During Exercise
Published on: October 7, 2015
Moritz Haugk1, Peter Stratil, Fritz Sterz
1Department of Emergency Medicine, Medical University of Vienna, Vienna, Austria.
Objective:
When treating patients with cardiac arrest with mild therapeutic hypothermia, a reliable and easy-to-use temperature probe is desirable. This study was conducted to investigate the accuracy and safety of tracheal temperature as a measurement of body temperature.
Design:
Observational cohort study.
Setting:
Emergency department of a tertiary care university hospital.
Patients:
Patients successfully resuscitated from cardiac arrest intended for mild hypothermia therapy.
Interventions:
Intubation was performed with a newly developed endotracheal tube that contains a temperature sensor inside the cuff surface. During the cooling, mild hypothermia maintenance, and rewarming phases, the temperature was recorded minute by minute. These data were compared with the temperature assessed by esophageal and blood temperature probes. Thereafter, tracheoscopy was performed to evaluate the condition of the tracheal mucosa.
Measurements And Main Results:
Approximately 2000 measurements per temperature sensor per patient were recorded in 21 patients. The mean bias between the blood temperature and the tracheal temperature was -0.16 degrees C (limits of agreement: -0.36 degrees C to 0.04 degrees C). The mean bias between the esophageal and tracheal temperatures was -0.22 degrees C (limits of agreement: -0.49 degrees C to 0.07 degrees C). Agreement between temperature probes investigated by the Bland-Altman method showed a mean bias of less than -(1/4) degrees C, and time lags assessed graphically by hysteresis plots were negligible. No clinically relevant injury to the tracheal mucosa was detected.
Conclusion:
Temperature monitoring at the cuff surface of an endotracheal tube is safe and provides accurate and reliable data in all phases of therapeutically induced mild hypothermia after cardiac arrest.
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Temperature Measurement Sites
Oral: When assessing oral temperature, the thermometer tip should be placed under the tongue in the posterior sublingual pocket. It offers accurate readings and can be...
Assessing Body Temperature - Temporal Artery
Step 1: Perform hand hygiene and don a fresh pair of gloves to prevent cross-infection and ensure patient safety.
Step 2: Explain the procedure to the patient to establish trust. Clear communication establishes trust with the patient, ensures they understand what to expect, promotes cooperation, and enhances comfort during the procedure.
Step 3: Assess the patient's forehead...
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Tympanic membrane
Step 1: Begin by practicing good hand hygiene to prevent the transmission of microorganisms.
Step 2: Turn on the thermometer and wait until the ready sign appears on the screen to ensure accurate measurement.
Step 3: Slide the probe cover in place to prevent cross-contamination.
Step 4: Instruct the patient to tilt their head to the side for comfort and check for cerumen...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...