Related Experiment Video
Updated: Jun 12, 2026

Method of Isolated Ex Vivo Lung Perfusion in a Rat Model: Lessons Learned from Developing a Rat EVLP Program
Published on: February 25, 2015
High tidal volume ventilation is not deleterious in infant rats exposed to severe hemorrhage
Vincenzo Cannizzaro1, Luke J Berry, Philip K Nicholls
1Division of Clinical Sciences, Telethon Institute for Child Health Research, Centre for Child Health Research, the University of Western Australia, Perth, Australia. vincenzo.cannizzaro@kispi.uzh.ch
Background:
Both high tidal volume (V(T)) ventilation and hemorrhage induce acute lung injury in adult rodents. It is not known whether injurious ventilation augments lung injury in infant rats exposed to severe hemorrhage.
Methods:
Two-week-old rats were allocated for ventilation with VT 7 mL/kg and positive end-expiratory pressure (PEEP) 5 cm H₂O (low V(T)) or V(T) 21 mL/kg and PEEP 1 (high V(T)) for 4 hours. Additional rats were subjected to volume-controlled hemorrhage and delayed saline resuscitation, followed by low V(T) or high V(T) ventilation for 4 hours. Nonventilated control groups were also included. Airway resistance and the coefficient of tissue elastance were derived from respiratory input impedance measurements using the low-frequency forced oscillation technique. Pressure-volume curves were obtained at baseline and at the end of the study. Interleukin-6, macrophage inflammatory protein-2, and tumor necrosis factor alpha were determined in bronchoalveolar lavage fluid (BALF) and serum.
Results:
In both healthy and hemorrhage-exposed animals, high V(T) resulted in reduced elastance (better lung compliance) and increased transcutaneous oxygen saturation. Interleukin-6 in BALF was greater in ventilated animals when compared with nonventilated controls, but not different among ventilated groups. No significant differences were found for all other inflammatory mediators, total protein concentration in BALF, and histology.
Conclusion:
High V(T) ventilation with low PEEP improves respiratory system mechanics without causing additional damage to healthy and hemorrhage-exposed infant rats after 4 hours of ventilation. This study highlights the tolerance to high V(T) ventilation in infant rats and underscores the need for age-specific animal models.
More Related Videos
06:22Surfactant Depletion Combined with Injurious Ventilation Results in a Reproducible Model of the Acute Respiratory Distress Syndrome (ARDS)
Published on: April 7, 2021
06:47A Pulmonary Trunk Banding Model of Pressure Overload Induced Right Ventricular Hypertrophy and Failure
Published on: November 29, 2018