Development of a Lateral Flow Immunochromatographic Strip for Rapid and Quantitative Detection of Small Molecule Compounds
Published on: November 13, 2021
[Nonradioactive iodine-labeled antibodies-inductively coupled plasma mass spectrometry for immunoassay]
Jing-Xi Li1, Xiao-Ru Wang, Zhi-Xia Zhuang
1Marine Ecology Research Center, First Institute of Oceanography of State Oceanic Administration, Qingdao 266061, China. jxli@fio.org.cn
In the present study, the system of nonradioactive iodine-labeled-antibodies linking inductively coupled plasma mass spectrometry for immunoassay was reported. The goat-anti-Escherichia coli and goat anti rabbit were considered as simulant antigen and antibody respectively in order to establish a new method of immunoassay by inductively coupled plasma mass spectrometry which has the advantage of high sensitivity, low detection limit and preferable linearity range. During the experiment, the N-bromosuccinimide, a mild oxidant, was used to oxidize the non-radioactive iodine (127 I) that labeled the protein. The method of nonradioactive iodine labeled protein was established and the best labeling condition was explored. The compound of I was purified by Sephadex G50 column chromatography, then the stability and activity were examined. The results showed that the labeling program was simple, reaction time was within two minutes, the labeling yield achieved 63.12% and none of I shed from the compound after 96 hours. The simulant antigen and antibody reacted on polystyrene microtiter plate and the I was detected by ICP-MS, the detection limit of the method was 0.12 mg x L(-1), relative standard deviation (n = 9) was less than 3% and the linearly dependent coefficient was 0.998 7. This system can also be used in analysis of other protein, nucleic acid and so on.
In the present study, the system of nonradioactive iodine-labeled-antibodies linking inductively coupled plasma mass spectrometry for immunoassay was reported. The goat-anti-Escherichia coli and goat anti rabbit were considered as simulant antigen and antibody respectively in order to establish a new method of immunoassay by inductively coupled plasma mass spectrometry which has the advantage of high sensitivity, low detection limit and preferable linearity range. During the experiment, the N-bromosuccinimide, a mild oxidant, was used to oxidize the non-radioactive iodine (127 I) that labeled the protein. The method of nonradioactive iodine labeled protein was established and the best labeling condition was explored. The compound of I was purified by Sephadex G50 column chromatography, then the stability and activity were examined. The results showed that the labeling program was simple, reaction time was within two minutes, the labeling yield achieved 63.12% and none of I shed from the compound after 96 hours. The simulant antigen and antibody reacted on polystyrene microtiter plate and the I was detected by ICP-MS, the detection limit of the method was 0.12 mg x L(-1), relative standard deviation (n = 9) was less than 3% and the linearly dependent coefficient was 0.998 7. This system can also be used in analysis of other protein, nucleic acid and so on.
More Related Videos
Related Concept Videos
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
Inductively Coupled Plasma Atomic Emission Spectroscopy: Principle
The ions and electrons produced interact with the fluctuating magnetic field created by a water-cooled...
Enzyme-Linked Immunosorbent Assay
There are many different types of ELISAs, but they all involve an antibody molecule whose constant region binds an enzyme, leaving the variable region free to bind its specific antigen. Enzyme-substrate reaction allows the antigen to be visualized or quantified.
Immunogold Electron Microscopy
Labeling DNA Probes
Radioisotopes, fluorophores, or small molecule binding partners like biotin or digoxigenin, are the most widely used reporter tags for labeling DNA probes. These labels can be attached to the probe DNA molecule via...
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences