Related Experiment Video
Updated: Jun 12, 2026

Rapid Viscoelastic Characterization of Airway Mucus Using a Benchtop Rheometer
Published on: April 21, 2022
Influence of particle size and material properties on mucociliary clearance from the airways
Andreas Henning1, Marc Schneider, Noha Nafee
1Chemical and Biomolecular Engineering, The Johns Hopkins University, Baltimore, Maryland, USA.
Abstract:
Mucociliary clearance (MC), designed by evolution to eliminate inhaled and possibly noxious material from the airways, considerably limits the benefit of inhalation therapy. Although the principles of MC seem to be understood, there are still many open questions on mucociliary particle clearance. In this study a trachea-based in vitro model was used to investigate the effect of particle size, zeta-potential, and mucoadhesive particle properties on mucociliary particle clearance. As different sized particles (50-6000 nm) were tested at equal mass concentrations, size related factors, namely particle number and particle surface area, varied by several orders of magnitude between the experiments. Surprisingly, particle clearance for 50 nm up to 6000 nm-sized polystyrene particles did not differ significantly (p < 0.05): 50 nm (2.9 +/- 0.6 mm/min); 100 nm (3.8 +/- 0.9 mm/min); 1000 nm (3.8 +/- 0.8 mm/min); 6000 nm (3.2 +/- 0.6 mm/min). In clear contrast, particles prepared from different PLGA-based copolymers (polylactic-co-glycolic acid) showed a significant effect on particle transport. PEG-PLGA particles (polyethylene glycol) showed the fastest and normal transport rates (5.9 +/- 1.7 mm/min) compared to the ICRP's (International Commission of Radiological Protection) standard value for average tracheal transport rates (5.5 mm/min). Mucoadhesive chitosan-PLGA particles were transported at the slowest rate (0.7 +/- 0.3 mm/min) of all particles tested. Overall, particle size and zeta-potential seem to be relatively uncritical, whereas material properties and the related particle surface chemistry significantly influence mucociliary particle clearance. Considering these findings in future drug formulation seems to be a promising strategy to improve inhalation therapy by prolonged particle/drug residence time within the airways.
Related Concept Videos
Factors Affecting Pulmonary Ventilation
Alveolar Surface Tension
The alveolar fluid lines the luminal surface of the alveoli and exerts a force called surface tension. This force is caused by the polar water molecules in the liquid being more strongly attracted to each...
Factors Affecting Dissolution: Particle Size and Effective Surface Area
Pressure Relationships in Thoracic Cavity
Breathing Mechanisms
Both intra-alveolar and intrapleural pressures rely on specific lung properties. The ability to breathe—allowing air to enter the lungs during...
Factors Affecting Renal Clearance: Drug's Physicochemical Properties and Plasma Levels
One important factor is the drug's molecular size. The kidneys readily excrete smaller molecules below 300 Daltons (Da). On the other hand, molecules weighing between 300 and 500 Da are excreted through both urine and bile. Larger molecules above 500 Da tend to be excreted less...
Chronic Obstructive Pulmonary Disease III: Chronic Bronchitis Features
Precipitate Formation and Particle Size Control
The obtained precipitate should be either a pure substance of known composition or easily converted to one by a simple process, such as ignition or drying. In addition, the precipitate should be insoluble and easily filterable. In general, filterability...

