Related Experiment Video
Updated: Jun 12, 2026

Evaluating Targeting Accuracy in the Focal Plane for an Ultrasound-guided High-intensity Focused Ultrasound Phased-array System
Published on: March 6, 2019
Focusing of high-intensity ultrasound through the rib cage using a therapeutic random phased array
Svetlana Bobkova1, Leonid Gavrilov, Vera Khokhlova
1Department of Acoustics, Physics Faculty, Moscow State University, Moscow, Russia.
Abstract:
A method for focusing high-intensity ultrasound (HIFU) through a rib cage that aims to minimize heating of the ribs while maintaining high intensities at the focus (or foci) was proposed and tested theoretically and experimentally. Two approaches, one based on geometric acoustics and the other accounting for diffraction effects associated with propagation through the rib cage, were investigated theoretically for idealized source conditions. It is shown that for an idealized radiator, the diffraction approach provides a 23% gain in peak intensity and results in significantly less power losses on the ribs (1% vs. 7.5% of the irradiated power) compared with the geometric one. A 2-D 1-MHz phased array with 254 randomly distributed elements, tissue-mimicking phantoms and samples of porcine rib cages are used in experiments; the geometric approach is used to configure how the array is driven. Intensity distributions are measured in the plane of the ribs and in the focal plane using an infrared camera. Theoretical and experimental results show that it is possible to provide adequate focusing through the ribs without overheating them for a single focus and several foci, including steering at +/- 10-15 mm off and +/- 20 mm along the array axis. Focus splitting caused by the periodic spatial structure of ribs is demonstrated both in simulations and experiments; the parameters of splitting are quantified. The ability to produce thermal lesions with a split focal pattern in ex vivo porcine tissue placed beyond the rib phantom is also demonstrated. The results suggest that the method is potentially useful for clinical applications of HIFU, for which the rib cage lies between the transducer(s) and the targeted tissue.
More Related Videos
05:56Evaluation of the Feasibility, Safety, and Accuracy of an Intraoperative High-intensity Focused Ultrasound Device for Treating Liver Metastases
Published on: January 9, 2019
07:38Real-time Monitoring of High Intensity Focused Ultrasound (HIFU) Ablation of In Vitro Canine Livers Using Harmonic Motion Imaging for Focused Ultrasound (HMIFU)
Published on: November 3, 2015
Related Concept Videos
Ultrasound II: Endoscopic Ultrasound and FibroScan
Endoscopic Ultrasound (EUS):
Ultrasonography
During an ultrasonography procedure, a handheld device called a...
Ultrasound I: Abdominal Ultrasonography
Abdominal ultrasonography, commonly known as abdominal ultrasound, is a vital, non-invasive medical imaging technique widely used in healthcare.
Procedure:
This diagnostic tool allows the clinician to visually inspect internal structures within the abdomen, including vital organs such as the liver, gallbladder, pancreas, kidneys, and spleen.
The abdominal ultrasound process begins with applying a special gel to the patient's skin over the abdomen. This gel enhances the...