Related Experiment Video
Updated: Jun 12, 2026

Fabrication of a Low-Cost, Fiber-Coupled, and Air-Spaced Fabry-Pérot Etalon
Published on: February 3, 2023
A Fabry-Pérot electro-optic sensing system using a drive-current-tuned wavelength laser diode
Wen-Kai Kuo1, Pei-Yu Wu, Chang-Ching Lee
1Department of Electro-Optics Engineering, National Formosa University, 64 Wenhua Rd., Huwei, Yunlin 63208, Taiwan, Republic of China. wkkuo@nfu.edu.tw
Abstract:
A Fabry-Pérot enhanced electro-optic sensing system that utilizes a drive-current-tuned wavelength laser diode is presented. An electro-optic prober made of LiNbO(3) crystal with an asymmetric Fabry-Pérot cavity is used in this system. To lock the wavelength of the laser diode at resonant condition, a closed-loop power control scheme is proposed. Experiment results show that the system can keep the electro-optic prober at high sensitivity for a long working time when the closed-loop control function is on. If this function is off, the sensitivity may be fluctuated and only one-third of the best level in the worst case.