Related Experiment Video
Updated: Jun 12, 2026

Dual Test Gas Pulmonary Diffusing Capacity Measurement During Exercise in Humans Using the Single-Breath Method
Published on: February 2, 2024
Reproducibility of peak oxygen uptake and other cardiopulmonary exercise parameters: implications for clinical trials
Steven J Keteyian1, Clinton A Brawner, Jonathan K Ehrman
1Division of Cardiovascular Medicine, Henry Ford Hospital, Detroit, MI 48202, USA. sketeyi1@hfhs.org
Background:
Clinical trialists involved in projects aimed at assessing the impact of a device or therapy on exercise capacity must select an end point that can detect a therapy-derived change and do so in a manner that is both sensitive to the change and valid. Using baseline data from the Prospective Evaluation of Elastic Restraint to Lessen the Effects of Heart Failure (PEERLESS-HF) trial, we describe the coefficient of variation (CV) for peak oxygen uptake (Vo2) and other parameters measured during a cardiopulmonary exercise (CPX) test.
Methods:
Prior to conducting CPX testing, a CPX core laboratory conducted training with testing staff at each site, and a standardized quality assurance protocol was completed. During screening, subjects performed two symptom-limited CPX tests (CPX-0 and CPX-1) within 14 days.
Results:
The CVs for peak Vo2, ventilatory efficiency, and ventilatory-derived anaerobic threshold were 5.9%, 4.8%, and 6.8%, respectively. During CPX-0, the percentage of subjects with a respiratory exchange ratio (RER) < 1.05 who increased their peak Vo2 by ≥ 6% during CPX-1 was 47%, compared with 12% of subjects also with an RER < 1.05 who experienced a decrease in peak Vo2 ≥ 6%.
Conclusions:
In a multisite clinical trial setting, we showed that the achieved test-retest reproducibility for peak Vo2 can be acceptable, as evidenced by a CV at 5.9%. Until more data are available to identify patients who may demonstrate greater test-retest variance and to avoid repeat testing in all subjects at baseline, clinical trialists might consider repeating tests when RER < 1.05.
Trial Registration:
clinicaltrials.gov; Identifier: NCT00382863.
Related Concept Videos
Exercise and Cardiac Output
Sustained exercise increases the muscles' oxygen demand, which can be met...
Pulmonary Function Tests
Pulmonary Function Tests are crucial diagnostic tools for assessing respiratory function, particularly in patients with chronic respiratory disorders. They comprehensively evaluate lung volumes, ventilatory function, breathing mechanics, diffusion, and gas exchange. These tests help diagnose pulmonary diseases and play a significant role in monitoring disease progression, evaluating disability, and assessing response to therapy.
PFTs involve using a spirometer, a...
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is important.