Related Experiment Video
Updated: Jun 12, 2026

Image Rendering Techniques in Postmortem Computed Tomography: Evaluation of Biological Health and Profile in Stranded Cetaceans
Published on: September 27, 2020
A comparison of three image fidelity metrics of different computational principles for JPEG2000 compressed abdomen CT
Kil Joong Kim1, Bohyoung Kim, Rafal Mantiuk
1Department of Radiation Applied Life Science, Seoul National University College of Medicine, Seoul 110-744, Korea.
Abstract:
This study aimed to evaluate three image fidelity metrics of different computational principles--peak signal-to-noise ratio (PSNR), high-dynamic range visual difference predictor (HDR-VDP), and multiscale structural similarity (MS-SSIM)--in measuring the fidelity of JPEG2000 compressed abdomen computed tomography images from a viewpoint of visually lossless compression. Three hundred images with 0.67- or 5-mm section thickness were compressed to one of five compression ratios ranging from reversible compression to 15:1. The fidelity of each compressed image was measured by five radiologists' visual analyses (distinguishable or indistinguishable from the original) and the three metrics. The Spearman rank correlation coefficients of the PSNR, HDR-VDP, and MS-SSIM values with the number of readers responding as indistinguishable were 0.86, 0.94, and 0.86, respectively. Using the pooled readers' responses as the reference standard, the area under the receiver-operating-characteristic curve for the HDR-VDP (0.99) was significantly greater than that for the PSNR (0.95) (p < 0.001) and for the MS-SSIM (0.96) (p = 0.003), and there was no significant difference between the PSNR and MS-SSIM (p = 0.70). In measuring the image fidelity, the HDR-VDP outperforms the PSNR and MS-SSIM, and the MS-SSIM and PSNR are comparable.
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System VI: Calcium -Scoring CT
Imaging Studies II: Ultrasonography

