Related Experiment Video
Updated: Jun 12, 2026

In Vivo Quantitative Assessment of Myocardial Structure, Function, Perfusion and Viability Using Cardiac Micro-computed Tomography
Published on: February 16, 2016
Iodine-123 metaiodobenzylguanidine imaging and carbon-11 hydroxyephedrine positron emission tomography compared in
Ichiro Matsunari1, Hirofumi Aoki, Yusuke Nomura
1The Medical and Pharmacological Research Center Foundation, Hakui, Japan. matsunari@mprcf.or.jp
Background:
Although both (123)I-metaiodobenzylguanidine ((123)I-MIBG) imaging and (11)C-hydroxyephedrine ((11)C-HED) positron emission tomography (PET) are used for assessing cardiac sympathetic innervation, their relationship remains unknown. The aims were to determine whether (123)I-MIBG parameters such as heart-to-mediastinum ratio (H/M) are associated with quantitative measures by (11)C-HED PET and to compare image quality, defect size, and location between (123)I-MIBG single-photon emission computed tomography (SPECT) and (11)C-HED PET.
Methods And Results:
Twenty-one patients (mean left ventricular ejection fraction, 39 ± 15%) underwent (123)I-MIBG imaging and (11)C-HED PET. Early (15-minute), late (3-hour) H/M, and washout rate (WR) were calculated for (123)I-MIBG. Myocardial retention and WR was calculated for (11)C-HED. Using a polar map approach, defect was defined as the area with relative activity <60% of the maximum. Both the early (r=0.76) and late (r=0.84) (123)I-MIBG H/M were correlated with (11)C-HED retention. (123)I-MIBG WR was correlated with (11)C-HED WR (r=0.57). Defect size could not be measured in 3 patients because of poor quality (123)I-MIBG SPECT, whereas (11)C-HED defect was measurable in all patients. Although defect size measured by early or late (123)I-MIBG SPECT was closely correlated with that by (11)C-HED PET (early: r=0.94; late: r=0.88), the late (123)I-MIBG overestimated defect size particularly in the inferior and septal regions.
Conclusions:
(123)I-MIBG H/M gives a reliable estimate of cardiac sympathetic innervation as measured by (11)C-HED PET. Furthermore, despite the close correlation in defect size, (11)C-HED PET appears to be more suitable for assessing regional abnormalities than does (123)I-MIBG SPECT.
Related Concept Videos
Imaging Studies for Cardiovascular System I:Echocardiography
Indications: Echocardiography is utilized to diagnose heart failure, valve disorders, and myocardial infarction. It also assesses cardiac structures' size, shape, and motion, evaluates...
Imaging Studies for Cardiovascular System V: CT
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Acute Coronary Syndrome III: Diagnostic Studies
Imaging Studies for Cardiovascular System II:Types of Echocardiography
Types of Echocardiography
Transthoracic Echocardiography (TTE)
TTE is the most common type of echocardiogram which involves placing a transducer on the patient's chest, emitting sound waves to create heart images. TTE is invaluable for evaluating the heart's size, structure, and motion, making it particularly useful for diagnosing...
Radiological Investigation III: Pulmonary Angiogram and PET Scan
Pulmonary Angiogram
A Pulmonary Angiogram is an invasive procedure involving injecting a contrast medium through a catheter threaded into the pulmonary artery or the right side of the heart to visualize the pulmonary vasculature. Computed Tomography (CT) scans have mainly replaced this...

