Related Experiment Video
Updated: Jun 12, 2026

One-step Metabolomics: Carbohydrates, Organic and Amino Acids Quantified in a Single Procedure
Published on: June 25, 2010
Tandem mass spectrometry screening for very long-chain acyl-CoA dehydrogenase deficiency: the value of second-tier
Ute Spiekerkoetter1, Ulrike Haussmann, Martina Mueller
1Department of General Pediatrics, University Children's Hospital, Duesseldorf, Germany.
Objective:
To evaluate newborn screening (NBS) for very long-chain acyl-CoA dehydrogenase deficiency (VLCADD), we further characterized newborns with elevation of one or all C14-carnitine derivatives on NBS from a total of 90 338 newborns.
Study Design:
Palmitoyl-CoA oxidation was performed in lymphocytes to define very long-chain acyl-CoA dehydrogenase function. Molecular analysis followed in children with residual activities<50%. The acylcarnitine pattern on days 2 to 3 of life was evaluated thoroughly to define possible discrimination markers.
Results:
Forty newborns with increased C14:1-carnitine were identified (1:2500). In 2 newborns, VLCADD was confirmed with enzyme and molecular analyses (prevalence, 1:50,000). One of these newborns had normal results on a second screening. Also, the combination of absolute acylcarnitine values and acylcarnitine ratios did not allow correct identification of the newborn as a patient with VLCADD.
Conclusions:
Reliable diagnosis is not feasible with acylcarnitine analysis alone. Enzyme analysis in lymphocytes is a reliable and rapid method for correctly assessing all newborns with VLCADD and should be carried out in all newborns identified during the first screening, regardless of the results of a later acylcarnitine profile.