Absolute spectral irradiance scale in the 700-2400 nm spectral range
Applied Optics
|June 23, 2010
Summary
A new absolute spectral irradiance scale was developed for the 700-2400 nm range using an absolute radiometer and interference filters. This scale shows excellent agreement with existing NIST standards, ensuring reliable spectral measurements.
Area of Science:
- Radiometry
- Optical Physics
- Metrology
Background:
- Accurate spectral irradiance scales are crucial for various scientific and industrial applications.
- Existing scales may have limitations in specific wavelength ranges or accuracy.
Purpose of the Study:
- To develop a new absolute spectral irradiance scale for the 700-2400 nm range.
- To ensure accurate and reliable spectral measurements in the near-infrared spectrum.
Main Methods:
- Utilized an absolute radiometer as the primary standard.
- Employed a series of narrow-band interference filters to define discrete wavelengths.
- Determined spectral irradiance of quartz halogen lamps at specific wavelengths.
- Interpolated values for intermediate wavelengths.
Main Results:
- Successfully established an absolute spectral irradiance scale for 700-2400 nm.
- Demonstrated agreement within +/- 1% when compared to NIST standards.
- Validated the scale's accuracy through comparison with blackbody radiance-based standards.
Conclusions:
- The newly developed spectral irradiance scale is accurate and reliable for the 700-2400 nm range.
- This scale provides a valuable tool for precise optical measurements.
- The scale's high agreement with NIST standards enhances confidence in its use.
Related Concept Videos
IR Spectrum
When infrared (IR) radiation passes through a molecule, the bonds stretch or bend by absorbing the radiation. This absorption creates the molecule's absorption spectrum, which is the plot of its percentage transmittance versus wavenumber.
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
Transmittance is defined as the ratio of the radiant power passing through a sample to that from the radiation's source. Multiplying the transmittance by 100 gives the percent transmittance (%T), which varies between 100% (no absorption) and 0% (complete...
IR Spectrometers
There are two main infrared (IR) spectrophotometers: dispersive IR spectrometers and Fourier transform infrared (FTIR) spectrometers. In a dispersive IR spectrometer, a beam of infrared radiation produced by a hot wire is divided into two parallel equal-intensity beams using mirrors. One beam passes through the sample, while another is a reference beam. The beams then move through the monochromator, which separates the radiations into a continuous spectrum of different frequencies. The...
Infrared (IR) Spectroscopy: Overview
When electromagnetic radiation passes through a material, atoms or molecules transition from a lower to a higher energy state by absorbing radiation corresponding to the energy difference between the two states. The absorption of infrared (IR) radiation causes transitions between vibrational energy levels in a molecule. Therefore, IR spectroscopy is a useful analytical tool for determining the molecular structure of molecules.
Different compounds display unique properties due to their...
Different compounds display unique properties due to their...
UV–Vis Spectrometers
The absorbance of UV and visible (UV–visible) radiations is measured using a UV–visible spectrophotometer. Deuterium lamps, which emit UV radiation, and tungsten lamps, which produce radiation in the visible region, are used as light sources in UV–visible spectrophotometers. A monochromator or prism is used for diffraction grating, i.e., to split the incoming radiation into different wavelengths. A system of slits is used to focus the desired wavelength on the sample cell. Samples for...
UV–Vis Spectrum
When light passes through a substance, a portion of the light is absorbed while the remaining light is reflected or transmitted. If the molecule absorbs light between the wavelengths of 180–400 nm range, the UV spectrum is obtained, and if it absorbs light in the 400–780 nm wavelength range, the visible spectrum is obtained.
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar absorptivity (ε) or log ε on the y-axis (ordinate)...
The UV–Vis spectrum of a molecule is the plot of its absorbance versus wavelength. The plot is drawn by taking molar absorptivity (ε) or log ε on the y-axis (ordinate)...
Spectrophotometry: Introduction
Spectrophotometry is the quantitative measurement of the absorption, reflection, diffraction, or transmission of electromagnetic radiation through a material as a function of the intensity and wavelength of the radiation. A spectrophotometer is a device used to measure the change in the radiation intensity caused by its interaction with the material.
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...
The essential components of a spectrophotometer include a source of electromagnetic radiation, a slot for placing a material to be analyzed, and a...